Last week I bought a second hand BAUKNECHT TRK4850 DRYER. It is a professional machine with many programs and switch options. I feared it would be a huge quest to find a manual. I was delighted when I found owner-manuals.com. After payment I received the file to download the next day already. The quality is great. I am very happy. Thanks!
but kindly the distributions of the operating programs not find in the owners manual,can you help me to understand the operating programs instructions thank you
Received my manual within 24 hours. Very clear scan of the manual I needed. Thanks!
Text excerpt from page 11 (click to view)
Wiring Diagram
N
220 240 0 1 2 3 4
2
1
A. IGNITOR SWITCH B. IGNITOR UNIT
L
Brown
Fault Finding
Preliminary Electrical Systems Check
Blue Green Yellow PLUG (with cover removed) Earth Wire Green/Yellow
()
FUSE
SOCKET (face view)
E( )
START Isolate appliance and carry out: A: Earth Continuity check.
Neutral Wire Blue
N
L
Blue Brown Green Yellow
NO
YES
Carry out: C: Polarity check.
Carry out: D: Resistance to Earth check.
Electricity supply should now be satisfactory.
Has inlet fuse blown?
NO
YES
A. EARTH CONTINUITY CHECK - Appliance must be electrically disconnected - meter set on W (Ohms) x 1 scale and adjust zero if necessary. a) Test leads from any appliance earth point to earth pin on plug. Resistance should be less than 0.1 W (Ohm), check all earth wires for continuity and all contacts are clean and tight. B. INSULATION CHECK - Appliance electrically disconnected, all switches ON. a) meter set on W (Ohms) x 1 scale. Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit. b) meter set on W (Ohm) x 100 scale. Repeat test with leads from L to E. If meter reads less than ¥ (infinity) there is a fault. NOTE - Should it be found that the fuse has failed but no fault is indicated - a detailed continuity check (i.e. by disconnecting and checking each component) is required to trace the faulty component. It is possible that a fault could occur as a result of local burning/arcing but no fault could be found under test. However a detailed visual inspection should reveal evidence of burning around the fault.
Inlet wiring faulty. Rectify any fault.
Isolate appliance and carry out: B: Insulation check. Rectify any fault including replacing fuses as necessary.