Thr Video Recorder i have is quiet Old and the Producer could Not help me. So i w as very glad to find an offer for the owners Manual for a very fair Price.a I obtained the original Manual very quick and I am happy to have it now.
The PDF copy was immediately available on download after the payment. However, I noticed that the document was in German, and Ihad to contact a German translator to get it translated it to English. The quality of document is legible can be used for my purpose.
The manual was complete and of great quality. Originally a tri-lingual file, I first received only one language. After a note to owners-manuals.com, I quickly received the remaining languages... Great service, definitely worth it.
Text excerpt from page 4 (click to view)
Hood Description
1) Control panel 2) Grease filters 3) Work-lights
Use
The hood may be used as follows: � Exhausting version � Recycling version
Exhausting version
The air is vented outdoors by a duct which must be connected to the coupling ring S (See figure 6 �Installation�). Choosing the exhausting pipe The coupling ring S has a diameter of 150mm. We suggest to use � 150 mm exhausting pipe.
Suggestions for the installation and use of the hood
� The horizontal sections of the pipe must be slanted slightly upwards (about 10%) to ensure an easy flow of the air outwards. � The best performance of the unit is obtained in the external exhaust model (suction), therefore in the limits of the possibilities it is advised to use the external exhaust (suction) type. � The best performances are obtained with short pipes (max. 4 m) and with few curves.
Recycling version
The air is filtered through two carbon filters (to install them see paragraph Carbon filter -) and recirculated into the room through the grating on the lower chimney part. Attention! If the hood is not supplied with carbon filter, then it must be ordered and mounted. This version is used when there is no exhaust duct for venting outdoors or when it is impossible to install one.
Electric connection
Before completing any connection, make sure the house voltage corresponds with the voltage indicated on the label affixed inside the hood. The hood is supplied with a standard plug; connect it to a correspondingly standard socket. In the case is intended to connect the appliance permanently to the mains after having removed the plug supplied, must be fitted a two-pole switch conforming to regulations with an opening distance between contacts of not less than 3mm. The manufacturers are not liable for any problems caused by the user�s failure to observe the above instructions. 7
Installation
When installed, the hood must be not less than 60 cm. above electric burners or 75 cm. above gas or mixed-fuel burners.
Warning!
� The hood cannot be connected to flues of other appliances that run on energy sources other than electricity. � When the hood is used at the same time of other appliances that run on energy sources other than electricity, provision must be made for an adequate supply of air.