Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Excellent concise manual. All needed information was included. Typeface and diagrams were clear. Very fair price considering what others are charging. Many thanks
 ;
Response is a little slow- I had to wait 12 hours to receive download link but it says that it may take up to 24hrs.
Manual is old and was not produced in PDF- scanned copy is exellent.
Overall- value for money- I recommend
 ;
Excellent quality and quickly delivered manuals at a fair price. Great care is taken in the reproduction process. Even photographs and highly detailed drawings are as clear as in the original. That cannot be said for some freelance manual copies I have obtained from the web. If you have exhausted your internet search of technical manuals, try Owner-Manuals.com. If they do not have it, I do not think it exists. Perhaps, if requested, they may be able to find it. Their resources are certainly greater than most. Shopping here certainly beats waiting for months or years for the manual you seek to appear in an internet auction or garage sale.
 ;
Very detailed product, also it is a scanning from original, very useful if you have to service this type of amplifier ! Very good product, very hard to find!
 ;
the Manual was made available as promised, the scans were excellent..Good Work !!!
PAGE 3 OF 3 NOTES/INSTRUCTIONS (CONT�D): Test procedure changes (Citation only)
ECO: 981782
A. Menu (brings up Setup Menu) with no video source. B. Adjust C711 on the Video board (the white variable capacitor) with a non-metallic screwdriver until the subcarrier display is stable (stops spinning) on a vectorscope. C. Select Options Setup. D. Set Video Fmt. to NTSC+ PAL. E. Press Menu to exit Options Setup. F. Select Program Setup and change the NTSC to PAL (bottom row on program 1 and re-adjust C711 on the Video board (the white variable capacitor) with a non-metallic screwdriver until the subcarrier display is stable on a vectorscope, monitor the main video output. G. When you switch between NTSC and PAL (by pressing the two program buttons 1=PAL and 2 =NTSC), you should see the vectorscope display lose lock (begin to spin). Re-adjust C711 until the display is stable for both NTSC and PAL. If you can not get the display to stablize for both, STOP HERE. Note the failure. The unit must be repaired. H. Get out of the Program Setup menu. Vector scope referenced above is the magni vector scope. ***Note that this section replaces the adjustment of C711 in preveous test procedures. The shunt jumper is not necasary for this adjustment.
|
|
 |
> |
|