Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Received my manual within 24 hours. Very clear scan of the manual I needed. Thanks!
 ;
Very clear scan, I recommend it. Definitely a must have for any 3362 owner.
Alpine could have written a slightly more complete manual, though. It's already pretty huge, but the unit has so many functions, I feel some more explanation would have been better.
Yamaha's manual of their comparable YDSP-1 is a little better in my opinion.
 ;
Immediate response with excellent service - highly reccommended
 ;
Correct manual received and of good quality but the contents of the file for the Service Manual for the same monitor is for a 20" TV not the RGB Monitor.
 ;
The owners manual for the Pioneer VSX-D603S was exactly what I needed. I received it in a timely manor and it was priced fairly. I definately will use your servise again. Thank You
Chapter 2 Pattern Analysis Examples Sort Pattern Examples
Methods for Sorting Data-to-Clock Intervals
You can use sorting when the Time Interval Measurement area (on the TIA Setup window) is set to Use data-to-clock intervals for display and analysis. In this case, the sorting process is the same as for a single input sort, but when a match is found, the data-to-clock interval is placed in the distribution (histogrammed). The primary difference is that the location of the R (result locator) determines if the data-to-clock interval is taken from the initial edge or the last edge of the data interval. For example, once a pattern match is found for the string (4,2R), the R location (2R) directs the Timing Pattern Analysis software to compare the last edge of the 2 code spacing to the nearest clock edge and histogram the resulting interval. A pattern match of (4,R2), directs the Timing Pattern Analysis software to compare the initial edge of the 2 code spacing to the clock and histogram that interval. Both an external clock and a computed clock can be used for sorting data-to-clock intervals.
2
NOTE
All of the prior examples have assumed that the histogrammed result is the code spacing interval associated with the R (result locator). This is true whenever Use on the TIA Setup window is set to �Input 1 only,� or �Input 2 only�. If the Use selection is something other than these, the histogrammed intervals are based on the Use selection. In such cases, the search pattern match is the same as it is for the single-channel examples, the difference is in the type of result that is histogrammed.
2-16