B. TROUBLE DIAGNOSES AND REPAIR BY SYMPTOM
The Wash Pump/Motor does not run. No Power on when the power button pressed.
� Close the Door Tightly. � Check the Door Switch in Latch Handle.
The plug is correctly inserted in the Socket-Outlet?
NO
� Insert the Plug Correctly. � Check the electricity is failed or not.
The Door is tightly closed?
NO
YES
YES
The Fuse or Circuit Breaker of house is O.K?
NO
� Replace the Fuse or Circuit Breaker of house.
The Pump/Motor is not blocked?
NO
� Remove the cause of block or replace the Pump/Motor.
YES
YES
The Thermal Fuse is O.K?
NO
� Check the Thermal Fuse and replace it.
The circuit of Pump/ Motor is O.K?
NO
� Repair the circuit.
YES
YES
The Power Switch or the Circuit is O.K?
NO � Check the Power Switch or the circuit and repair it.
The Thermal Protector of Motor is tripped?
YES
� Cool the Motor Until the Thermal Protector reset.
NO
YES
Replace the Pump/Motor
The C-Trans Circuit is O.K? NO � Check the C-Trans Circuit. and repair it.
YES
C h e c k t h e C o n t r o l l e r. ( P o w e r C i r c u i t )
- 20 -