Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This manual is very good. 303 pages scanned in a very high resolution. My camera has bad, leaking capacitors which all of the V5000 models are suffering from these days.
There is a huge part list with all capacitors, transistors etc. in this manual which helped me a lot. Otherwise I would not have been able to buy replacement parts.
The dissassembly guide is very enormous and detailed. Unlike on the Panasonic MS1 manual I downloaded here it actually looks like the real parts look. And the screws are labeled correctly, so you shouldn't have any left after the repair. ;)
 ;
has all the schematics you could need,and very well laid out format also has all part numbers along with an exploded view which is helpful
 ;
Very nice to have! Now it is no problem to understand how it is put together.
Helps me a lot.
 ;
good scans, all is clear. all pages in order. recommended
 ;
Très-très bon site, facile, très bon prix.
Au futur besoin, je n’hésiterais à faire appel à vous.
Merci
2 Pole Magnet
(2) Adjustment must be operated in a dark room (simple dark room)
2. Adjustment
4 Pole Magnet
(1) Test Equipment: Oscilloscope, 100:1 Probe (2) Connect oscilloscope to cathode of R, G, B(R926R/B/G: SCREEN ADJ on the PCB) and GND. (3) Turning Screen Volume (R/G/B) in Focus Pack and adjust R/G/B is 165V!0.5V.
6 Pole Magnet
165V±0.5V 0V
O
Centering Magnet Adjustment
1) Receive the EU 05 CH signal.(PR.1 : PAL B/G 175.25MHZ) 2) Press the keys of Remote Controller for adjustment to reset the convergence. a.Adjustment mode:Press the IN-START key. b.Data reset : Press 0 KEY. c.Adjustment mode cancellation : Press the ENTER key. (4) After adjustment complete, exit the RASTER adjustment mode using ENTER key and exit the SVC adjustment mode using INSTART key.
1. Preliminary steps
O
Deflection Adjustment
1) NTSC mode should be adjusted after adjusting PAL mode. 2) NTSC adjustment should be done in STANDARD mode of picture after receiving 13CH signal or MULTI 48CH signal,and PAL adjustment should be done in STANDARD mode of picture after receiving EU05 CH. 3) Reset the data in convergence adjustment mode,quit the mode. Adjustment Mode : Press the IN_START key and then �0� key. Data reset : Press the �0� key. Adjustment mode cancellation :Press the ENTER key. 4) Display only the Green raster using lens covers to block Red and Blue.
1. Preliminary steps 2. Adjustment
1) Operate adjustment about Red,Green,Blue centering magnet. 2) SGS-THOMSON Convergence assy Adjust until the center of blue signal is shifted up to 40mm left from that of green signal and center of red signal is shifted up to 40mm right from that of green signal with turning the centering magnet. 3) After adjustment, re-adjust convergence data and exit the adjusting mode. a.Adjustment mode:Press the IN_START key. b.Data reset : Press 0 KEY. c.Adjustment mode cancellation : Press the Enter key.
2. PAL Mode Deflection adjustment
O
High Voltage Regulation Adjustment
Digital Multi-Meter(DMM)
Do not adjust V-LIN, S-COR, A-BOW, A-ANG, UCPIN, LCPIN, V-ASP, V-SCR in PAL MODE. At SVC mode, press the �0� key get into the deflection adjustment mode. 1) VS (Vertical Shift) Adjust until the geometric vertical center line is accord with the vertical center line of screen JIG in EU 05 CH by pressing the VOLUME F ,G key. 2) VA (Vertical Amplitude) Adjust until sixth vertical line from upper and lower center of the screen is accord with the last point of the frame. 3) HS (Horizontal Shift) Adjust until the geometric horizontal center line is accord with the horizontal center line of screen JIG. 4) EW (East-west Width) Adjust until the outermost left and right vertical line of the screen is accord with the last point of the frame. 5) EP (East-west Parabola) Adjust so that middle portion of the outermost left and right vertical line looks like parallel with vertical lines of the PRT.
1. Test Equipment 2. Preparation for Adjustment.
Select picture mode to �DYNAMIC� in no signal input.
3. Adjustment
1) Press the IN_START key and then press �1� key.(HV ADS) 2) Connect �+� terminal(Red) of DMM to the P415 of the Deflection PCB, [+] and the �-�terminal(Black) to the P416,[-]. 3) Adjust VR401 so that the voltage of multimeter to be below voltage. Voltage : 21.7 ! 0.1V. 4) Exit the adjustment mode by pressing the enter key
O
CUT-OFF Voltage Adjustment
(1) Select INSTART key on the Remote Control and then select �2 SCREEN ADJ� move the cursor or using the key No..
1. Preliminary steps
- 14 -
|
|
 |
> |
|