The service manual when downloaded and printed out was clear and easy to read. I would have liked to have been able to enlarge some details, but this was not possible as the file permissions did not allow this. The service was very good. The time taken from placing my order to downloading the document was only a few minutes.
 ;
The manual is useful for trouble shooting for an old instrument. It saved money,and let me enjoy DIY.
 ;
Perfect source of information for replacing the HDD and performing general diagnostics.
 ;
Perfect source of information for replacing the HDD and performing general diagnostics.
 ;
Very good scanned copies. Quick response and reasonable price. Thanks for service!
No Raster on Component signal
Repeat [A] Process
Pass
Check the signal of Q310,Q315,Q316
Fail
Change Q310,Q315,Q316
Pass
Check the input/ output of IC1
Fail
Re-soldering or Change the defect part
Check the input/output of IC500, IC600
Fail
Re-soldering or Change the defect part
Pass
Check the input/ output of IC901
Faill
Re-soldering or Change the defect part
Pass
Check input source cable and jack
- 17 -
|
|
 |
> |
|