PDF Contains
Technical Data, Mechanical data, Detailed Circuit diagram with components value, PCB layout. Actual PCBs Print. Component List, Spare parts code list and Input output detail. It cover LBB1211, LBB1212, LBB1213, LBB1216, LBB1217.
It is the actual Service Manual for SQ10
 ;
very good manual with clear electrical schemes. Very helpful to find wat was wrong inside my microwave.
 ;
Hi, thankyou for providing the Nordmende Globetrotter original manufacturer's repair manual. Quality is very good and sharp - the PDF file was comfortably small to download. The only question is: why did it take so long to become ready for download?? Many thanks anyway, I fixed the fault in the radio thanks to the circuit.
regards: Nick
 ;
This was super service.Ordered this manual and was reading the download an hour later
WASH HEATER TROUBLE
I WD(M)-8070F(H)B, WD(M)-1070(5)F(H)B, WD(M)-1170(5)F(H)B, WD(M)-1270(5)F(H)B, WD(M)-1370(5)F(H)B WD(M)-8074F(H)B, WD(M)-1074(6)F(H)B, WD(M)-1174(6)F(H)B, WD(M)-1274(6)F(H)B, WD(M)-1374(6)F(H)B WD-8078FHB, WD-1078FHB, WM-1171(6)FHB, WM-1371(6)FHB, WD-1271FB(B), WD-1071FB(B)
PWB ASSEMBLY (MAIN)
When checking the voltage between connector the PWB assembly (Main) during whites washing ,Is the voltage 220 - 240V ~ ?
220 - 240V~
RED YELLOW
NO
Replace the PWB assembly (Main).
YES
After power off,is the resistance of wire (RED-YELLOW) connectors between 10 to 30 ?
1 2 3 4
YES
Normal.
NO
After power off and the heater terminal is disconnected, is the resistance 10 to 30 ?
NO
Replace the heater assembly.
I WD-8070F(H), WD-1070(5)F(H)
When checking the voltage between two receptacles of the PWB assembly (Power) during washing. Is the voltage 220-240V?
220-240V
NO
Replace the PWB assembly (Power).
YES
After power off, is the resistance between yellow wire and red wire of connector 10 to 30 ?
YES
Normal.
NO
After power off, is the resistance of heater 10 to 30 ?
NO
Replace the heater assembly.