Check the insertion of part and replace of component part
2.
I2C Control Signal
SCL -Check Pont : R107 U201(155pin),U204(6pin), U401(41pin),U501(11pin) R452.
SDA -Check Point : R108 U201(156pin),U204(5pin), U401(40pin),U501(12pin) R451.
Failure Causes and
Solution � No Signal � message will be Display at TV Screen.
if Voltage is drop SCL as well as SDA. therefore each of part check
have to SCL with SDA of Voltage 3.2 ~3.5V. are replace of component Part, Check the
Check the install chip-position and short of solder, cold solder, etc. Where insertion of part
|
|
|
> |
|