|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Thanks so much for the Owner's manual for my Sony PS - FL1. I had purchased the turntable off of eBay. It came in and looked great. Packed well and appeared to be great. I balanced and aligned the tone are and hooked it up. When trying to play a record the tone are would move to the right place and just before it would drop to play it moved back off the edge of the record before touching down. I searched the net for an answer to this issue. No luck. Then I purchased the owners manual and sure enough there was a place to adjust where the stylus touched down. That adjustment solved the problem and saved me a $35 feet to have the player checked out. The manual is well written and easy to understand. It is a must have for anyone with this front loading Sony turntable.
 ;
Some years back I pruchased a Sansui G-9000. I had it cleaned up and a problem with the left channel repaired. When I got it back I hooked it up to my tape decks, turn tables, TV and it played great. The only thing I was not really satisfied with was the performance of my Graphic Equalizer. I purchased this owner's manual had poured myself a cup of coffee. The manual is well organized and written in plain language. It also contained the solution to my dissatisfaction. By using the preamp connections coupled I was able to run everything through my graphic equalizer and now enjoy the full potential of my complete system.
 ;
An excellent service for the price, however, it would also have been handy if the troubleshooter pages were included. The manual is only sent in the language of your country, thus it looks as though there are some pages missing. Otherwise highly recommended.
 ;
I am happy to get a rare TECHNICS SH-9090 Owner's Manual by PDF in clear copy.
 ;
Hr, klasse , good manual, verry fast on my e-mail, very usefull manual. rgds; ahm zeegers
5. Depress the gas control slightly and turn anti-clockwise until the indictor mark is aligned with the letters LOW. The burner will now be at minimum rate. 6. To turn the appliance �off�, return the control to the �OFF� position. 7. If for any reason the fire cuts out, return the control knob to the `OFF� position and wait 3 minutes before relighting. 8. In the event of failure of the igniter the fire may be lit by placing a lighted taper or match at the pilot position at the same time depressing the gas control in the IGN position. 5(029$/ 2) '(%5,6 RU 6227 '(326,7 Debris from any source or any soot formed shall require removal. Allow the appliance to cool for two to three hours before removing all of the coals and ceramic blocks for cleaning purposes. Once all the ceramics are removed from the fire bed check that no debris is located in the burner slots. If any debris is present it may easily be removed by using a small piece of thin cardboard to ease out any foreign matter. Be sure to remove the cardboard after use. Cleaning should be carried out in a well-ventilated area or in the open air, by gently brushing with the pieces held away from your face so that you avoid inhaling the dust. We do not recommend the use of a normal domestic vacuum cleaner, which may blow dust back into the air. 6(77,1* 83 7+( &2$/ %(' (See the identification sheet figure 13) Components Coal support shelf. 10 Large Coals. . Artificial coal front. 15 Small Coals The coal support shelf is positioned on the fibre support metalwork, ensure that the shelf sits against the two stops which are to prevent the shelf sitting on the burner outlet. Place the simulated coal front in position as shown in Fig.6, three tabs are provided to locate. The one-piece coal support shelf is constructed to allow three levels of coal support; these three levels are shown in Fig 6, the plan view of the bed. &2$/ /$<287 First Layer. Position 3 large and 6 small coals across the gap between the front simulated coal and the lower level of the coal support shelf. Position 4 large and 3 small coals on the middle level of the coal support shelf. Position 3 large coals on the upper level of the coal support shelf. See figure 7. Second Layer. Position 6 small coals to fill the gaps between the coals on the lower level and middle level of the coal support shelf. See figure 8. To obtain the best visual appearance it may be necessary to make slight adjustments to the position of the coals. NOTE: Additional coals must not be used. If any of the coals or the coal bed becomes damaged, lost or broken, genuine manufacturer�s replacements must be obtained (part numbers listed in short spares list) before the appliance is used. 9(17,/$7,21 Purpose built ventilation is not required for this appliance in GB only. For Ireland (IE) ventilation is required with a minimal cross sectional area of 100 sq. cms and should be checked regularly to ensure that it is free from obstruction. It must be fitted in accordance with the rules in force. &/($5$1&( 72 6+(/9(6 Minimum clearances to underside of a 150mm (6ins) combustible shelf from the top of the fire opening must be 228mm (9ins). Add 12.5mm (1/2in) to this clearance for every 25mm (1in) increased depth of shelf. &/($5$1&( 72 6,'(6 Minimum Clearance required to any combustible material to the side of the appliance must be 150mm (6in) The list of coal part numbers that the user can replace is at the back of this document. This appliance is intended for decorative purposes.
Page 3
|
|
 |
> |
|