Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I AM HIGHLY IMPRESSED BY THE EASE OF USE OF THIS DOWNLOAD SERVICE. INSTRUCTIONS ARE CLEAR AND SIMPLE TO FOLLOW....EVEN BY TECHNOPHOBES SUCH AS MYSELF. THE EMAILS POINT YOU IN THE RIGHT DIRECTION...ITS SO EASY PEASY. THE DOWNLOAD CHOICE OF USER MANUALS IS EXTENSIVE AND I COULD NOT FIND A CHEAPER OR MORE EFFICIENT SERVICE ON THE INTERNET. I COULD NOT HAVE MADE A BETTER CHOICE OF INFORMATION PROVIDER. SHOULD I EVER NEED ANOTHER USER MANUAL, THEN THIS IS THE FIRST CHOICE SITE. COULD NOT BE BETTER PLEASED!!!!!!!...MANY THANXES FROM JIM BURNS
 ;
I was impressed with the quality of service (frequent e-mails to let you know the status of your order), and the speed at which the download became available. The manual was a life saver and was not easy to track down. Thank you for such an excellent service.
 ;
the manual was just what i wanted it had all the revelent information required to operate the hifi .Iwould use any manual i downloaded for any item which needs a manual
 ;
Die gewünschte Bedienungsanleitung wurde vereinbarungsgemäß in deutsch bereitgestellt. Sie ist gut lesbar. Kein Kauderwelsch.
Danke für den Service.
 ;
GOOD SERVICE MANUAL GOT ALL THE INFO. THAT I NEEDED..
Electrical Requirements
Electrical Grounding Instructions This appliance is equipped with a three-prong grounding plug for protection against possible shock hazards. If a twoprong wall receptacle is encountered, the customer is required to contact a qualified electrician and have the twoprong wall receptacle replaced with a properly grounded three-prong wall receptacle in accordance with the National Electrical Code. Room air conditioners are designed to operate according to requirements on the nameplate and as shown in Figure 1. Fuse or circuit breaker ratings must be according to the fuse instruction label and as shown in Figure 1. Do not plug models marked �Use on Single Outlet Circuit Only� into a circuit with another appliance or light fixture.
Safety Features
This room air conditioner is equipped with an electronic control to improve comfort and ensure reliability.
Compressor Lockout To extend the life of the compressor a three minute time delay will occur when:
� � � Electrical power is first supplied to the unit The thermostat is turned down immediately after the compressor stops running. The Fan Control is quickly turned from FAN ONLY to COOLING mode or vice versa.
WARNING
To avoid death, personal injury or property damage due to electrical shock, this unit must be grounded. Do not under any circumstances cut or remove the round grounding prong from the plug. Do not use a two-prong adapter.
Low Voltage Protection This unit is equipped with �brownout� protection. In case of an extreme brownout, the Amana control will interrupt power to the unit to prevent compressor failure. When the line voltage reaches at least 180 VAC, the control will reenergize your unit. Note: A compressor lockout will occur after the unit is re-energized.
WARNING
To avoid death, personal injury or property damage due to electrical shock, do not use an extension cord. Do not pinch the power cord. Do not remove the warning tag from the power cord.
Advantages of Amana�s Electronic Controls
�Digital Temperature Setting
- Temperature can be set from 16°C to 32°C in 1°C increments
RECEPTACLE
PLUG
�Digital Temperature Display
- Shows indoor room temperature in FAN ONLY mode - Shows desired temperature setting in other modes �Computer Memory that Remembers - The unit remembers the last settings used when last turned on.
�TempAsure® Thermostat
250 V - 16 AMP
- Maintains set temperature within 1.0°C for maximum comfort
�Smart Cool �Energy Saver with TempAsure® air sampling
Figure 1
�Delay Timer
2
|
|
 |
> |
|