thanks for this download i got a pioneer bdp-lx70a blu-ray player and it had no manual i search everywhere on the internet and came across owner-manuals.com and i found that it was so easy to find and downloaded from this site if i ever need a manual again this would be the first place that i would come too thanks guys
 ;
Superb! It's the original manual. We can now use our old calculator with its full function.
 ;
This is a very well written and comprehensive manual. It answered all our queries.
2. Connect the Batteries
Note: All UPSs ship with the batteries disconnected. In addition, 5000 VA units have the batteries shipped outside the UPS case so you must install the batteries before connecting them. If you need to ship the UPS you must disconnect the batteries prior to shipment in order to comply with U.S. Federal Regulations. Refer to Appendix C: Transporting Your Smart-UPS, page 27, for details. Graphics are not drawn to scale. They are shown for reference only. Tower Units 1. Grasp the top edge of the bottom front cover and tilt it out.
5000 VA
For 5000 VA units: Remove the front bezel by grasping the finger clips on the side of the bezel and carefully loosening the four (4) snaps. Skip to step 3.
2. 3.
Unhook the bottom section of the front cover from the chassis and set it aside. Use a screwdriver or a coin to remove the two (2) battery door screws and open the door.
4.
For 1400 � 3000 VA units: To connect the battery (or set), press the gray connector into the plug at the top of the battery housing. Note: The 5000 VA model has four (4) battery packs that must be installed. Be careful lifting the batteries - they are heavy. Support the bottom of the batteries as you move them.
5.
For 5000 VA units: Hold the battery pack so that the leads are on top. Slide the battery pack into the UPS. Press the gray connector into the plug at the top of the battery compartment. Tuck the white cord (that serves as a handle for the connector) neatly to the side. For 5000 VA units, repeat step 5 for the remaining three (3) battery packs. Close the battery door, replace the screws, and replace the lower front cover.
6. 7.
5
990-7031D, Revision 5 5/01
|
|
 |
> |
|