Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
The Technics manual was very clear and I was able to solve my technical problems.
I did not think that anyone kept these manuals and was pleasantly surprised to find them on the Internet and at an affordable price.
I would recommend Owner Manuals as a first source of technical products for ‘dated’ equipment manuals.
Ian
 ;
The content of the manual was not found on the Internet and was a hard find. I check the net for 5 hours until I came across this web-site. When I did find the book it Auto loaded into my IPAD PDF shelf for books for review at anytime. Overall I am satisfied with the book and it answered all my questions. This repair book is obsolete because the product I bout it for is pretty old. Thanks for the help with the download and even having the manual. Thanks 73's K5HRD
 ;
Excellent manual including schematics. The service was great and the manual helped complete the job.
 ;
It was magic after so many years to still be able to source this info. It was equally amazing to return my Pioneer receiver to it near new sound quality AFTER NEARLY 30 YEARS! Thank you for this ability!
 ;
Very quick and easy website to use and fast download of manual, quality of manual is excellent and will be pleased to use this service again in the future, thanks so much!
CONVERGENCE CRT CUT-OFF, BACKGROUND AND SUB-CONTRAST ADJUSTMENT
BGR ADJ. 2. Using the remote controller, call NORMAL mode. ADJUSTMENT NO VIDEO signal.
2
14A1-RU 14A2-RU
No. point Adjusting procedure/conditions Waveform and others
CONVERGENC Receive the "Crosshatch Pattern" signal. 1 CRT CUTOFF 1. Switch TV to VIDEO mode,BLUE BACK OFF, with ( To be done (I C BUS 2. Press R/C to set Picture Normal condition.
G adjustment. 1. Turn the 4-pole magnet to a proper opening anIC801.(TP851) R
3.0Vdc
after purity STATIC CONVERGENCE B CONTROL) 3. Connect the oscilloscope to Red OUT from
gle in order to superpose the blue and red colours. Range : 1 V/Div (DC)
RGB R
2. Turn the 6-pole magnet to a proper opening anFig. 5-1 Sweep : 5 msec/Div
0
gle in order to superpose the green colour over 1 V blue and red colours. 4. Adjust SCREEN VR ,so that the tip of signal reach 3.0 Vdc + 0.1 Vdc.
DYNAMIC CONVERGENCE G Adjust convergence on fringes of the B 2 SUB-BRIGHT1. Call " SUB-BRI" in service mode. (Receive CrossFig. 5-2 2 (I C BUS line 1, 2 and 3 have the same darkness
B
NESS hatch pattern with 5 black level windows) screen in the following steps. ADJUSMENT 2. Adjust SUB BRIGHT " bus data in order that a) Fig. 5-1: Drive the wedge at point "a" and swing the deflection coil upward.
b) Fig. 5-2: Drive the wedge at points "b" and "c" RGB CONTROL) wherelse is slightly brighter than line 1, 1 2 3 4 5
c) Fig. 5-3: Drive the "c" wedge deeper and swing R line 4. 1, 2, 3 are in same black level.
swing deflection coil downward. 3 and finally line 5 will be the brighter than G
the deflection coil rightward.
d) Fig. 5-4: Drive the "b" wedge deeper and swing 3 WHITE BAL1. Receive the "Monoscope Pattern" signal. Refer to Page 6.
2. Fix all wedges on the CRT and apply glass Fig. 5-3 ICE MODE 3. Connect DC miliammeter between the TP 602 Y : 0.310 3. Apply lacquer to the deflection yoke lock screw, G 7500°K ( white ). DOWN by volume key.
R
the deflection coil leftward. ANCE SERV2. Press R/C to set Picture NORMAL condition. # 7500° K X : 0.300
tape over them. BGR ADJ. (I2C BUS ) TP 603 ( + ).
CONTROL) 4. Check Beam current should be around 800µA) ( MINOLTA COLOUR ANALYZER
magnet unit (purity, 4-pole, 6-pole magnets) and B 5. Set it to service mode and adjust the DRI-GS, & CA-100) magnet unit lock screw. DRI-BS data to have a colour temperature of *NOTE: Above DATA can be UP/
8
Wedge "a" LUMINATE Y signal. 20"/21" 10cd/m2 120cd/m2
Finally received the Red-only and Blue-only sig6. Receive "WHITE" pattern, WITH BURST signal, nals to make sure there is no other colours on the Fig. 5-4 and set BRIGHTNESS Y by generator, to ** 10 LOW HIGH screen. cd/m2 (MINOLTA CA-100) by reducing 14" 10cd/m2 200cd/m2 7. Adjust "CUT-R" & "CUT-G" to get 7,500. Then go
back NORMAL mode (HIGH BRIGHT**) to check * 7500° K About
100° colour temperature. If out of range, back to (1). DRI-GW="DRI-GS"DATA-5
DRI-BW="DRI-BS" DATA-5
Lacquer Note: This adjustment must be done after Wedge "b" "c"
warming up the unit for 30 minutes or longer with a beam current over 500µA. * ADJUST DRI-GC/GW, DRI-BC/BW as following DATA, after finishing DRI-BS and DRI-GS DATA ADJUSTMENT.
6-pole magnet DRI-BW="DRI-BS"-7*DRI-RC=25*, DRI-
4-pole magnet DRI-RW=32 (FIXED), DRI-GW="DRI-GS"-7*,
BC="DRI-BS", DRI-GC="DRI-GS"-7* CRT neck 4 Maximum 1. Receive the "Monoscope Pattern" signal. beam check 2. Press R/C to set Picture NORMAL condition.
Purity magnet (Full Scale: 3 mA Range) Lacquer 40cm and TP602 (�).
3. Connect the DC miliammeter between TP603 (+) 4. Beam current must be within 800 ± 100 µA.
8-1 8-2
 $4.99 14A1RU SHARP Owner's Manual Complete owner's manual in digital format. The manual will be available for download as PDF file aft…
|
|
 |
> |
|