Manual is in German but complete. I needed this one to fix a long lasting problem with the internal PSU of the camera. Most of the capacitors begin to leak after a few years wich results in the inability to power on the camera. When you try to turn it on the power led flickers and the unit directly turns off. Thanks to this manual I was able to locate all bad cap's and to dis- and reassemble the camera without any problems.
We received the manual in a timely manner and it was exactly what we were expecting.
Text excerpt from page 17 (click to view)
14AG2-SMK3-A
2. PURITY ADJUSTMENT
No. 1
Adjustment point PURITY ADJ.
Adjustment procedure/conditions 1. Receive the GREEN-ONLY signal. Adjust the beam current to ~700 µA . 2. Degauss the CRT enough with the degausing coil. Note: Follow the Job Instruction Sheet to adjust the magnetic field. (Reference: page 3-5) 3. Maintain the purity magnet at the zero magnetic field and keep the static convergence roughly adjusted. 4. Observe the points a, b,as shown in Fig. 1-1 through the microscope. Adjust the landings to A rank requirement. 5. Orient the raster rotation to 0 eastward. 6. Tighten up the deflection coil screws. Tightening torque: 108 ± 20 N (11 ± 2 kgf) 7. Make sure the CRT corners landing meet the A rank requirements. If not, stick the magnet sheet to correct it. Note: This adjustment must be done after warming up the unit for 30 minutes or longer with a beam current over 700 µA. Note: Set to service mode by remote controller then press factory process R/C RGB key to change to RGB mono colour mode. * For the following colours press R/C RGB(Hex 7E) key to change.
GREEN ONLY BLUE ONLY Signal-colour screen cleared RED ONLY
Waveform and others
a
b
30mm
Fig. 1-1
30mm
A
B A=B
Fig. 1-2
Rank "A" (on the right of the CRT)
A
B A=B
Fig. 1-3
Rank "A" (on the left of the CRT)
* Press R/C RGB key for 1 second in NORMAL MODE, the colour will change to RGB mono colour mode.