|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Perfect source of information for replacing the HDD and performing general diagnostics.
 ;
Very good scanned copies. Quick response and reasonable price. Thanks for service!
 ;
Good. Good. Good. Good. Good. Good. Good. Good. Good. Good. Good. Good. Good. Good.
 ;
Very helpfull information and I highly recommend this source for needed information about your products.
 ;
More than pleased with my prurchase, very good product for the price.
14GT15 14GT20
PURITY ADJUSTMENT
No. Adjusting point 1 PURITY ADJ. Adjusting procedure/conditions 1. Receive the GREEN-ONLY signal. Adjust the beam current to about 500 µA. 2. Maintain the purity magnet at the zero magnetic field and keep the static convergence roughly adjusted. 3. Observe the points a, b as shown in Fig. 4-1 through the microscope. Adjust the landing to the A rank requirements. 4. Orient the raster rotation to 0 eastward. 5. Tighten up the deflection coil screws. » Tightening torque: 108 ± 20 N (11 ± 2 kgf) 6. Make sure the CRT corners landing meet the A rank requirements. If not, stick the magnet sheet to correct it. Note: This adjustment must be done after warming up the unit for 30 minutes or longer with a beam current over 500 µA. Waveform and others
a
b
Fig. 4-1
A
B A=B
Fig. 4-2 Rank "A" (on the right of the CRT)
A
B A=B
Fig. 4-3
Rank "A" (on the left of the CRT)
12
|
|
 |
> |
|