Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
I am proud of you. In the future, I benefited from your services.
;
I found this manual to be complete in every detail. Besides the schematic it has a complete set of alignment instructions which are easy to understand. It also includes a complete parts list as well as an explanation of how the power supply and safety shutdown circuits operate. Even a schematic of the tuner is included.
;
The product was good and just what I needed, however I had moderate difficulty with the down load because the sight would not recognize my pass word. I was finally given a direct link to the manual and that worked.
;
Very quick and easy website to use and fast download of manual, quality of manual is excellent and will be pleased to use this service again in the future, thanks so much!
;
It is an very good and clear scanned service manual.
very recommended.
ELECTRICAL ADJUSTMENTS
3. PURITY AND CONVERGENCE ADJUSTMENTS
NOTE 1. Turn the unit on and let it warm up for at least 30 minutes before performing the following adjustments. 2. Place the CRT surface facing east or west to reduce the terrestrial magnetism. 3. Turn ON the unit and demagnetize with a Degauss Coil. 3-1: STATIC CONVERGENCE (ROUGH ADJUSTMENT) 1. Tighten the screw for the magnet. Refer to the adjusted CRT for the position. (Refer to Fig. 3-1) If the deflection yoke and magnet are in one body, untighten the screw for the body. 2. Receive the green raster pattern from the color bar generator. 3. Slide the deflection yoke until it touches the funnel side of the CRT. 4. Adjust center of screen to green, with red and blue on the sides, using the pair of purity magnets. 5. Switch the color bar generator from the green raster pattern to the crosshatch pattern. 6. Combine red and blue of the 3 color crosshatch pattern on the center of the screen by adjusting the pair of 4 pole magnets. 7. Combine red/blue (magenta) and green by adjusting the pair of 6 pole magnets. 8. Adjust the crosshatch pattern to change to white by repeating steps 6 and 7. 3-2: PURITY NOTE Adjust after performing adjustments in section 3-1. 1. Receive the green raster pattern from color bar generator. 2. Adjust the pair of purity magnets to center the color on the screen. Adjust the pair of purity magnets so the color at the ends are equally wide. 3. Move the deflection yoke backward (to neck side) slowly, and stop it at the position when the whole screen is green. 4. Confirm red and blue colors. 5. Adjust the slant of the deflection yoke while watching the screen, then tighten the fixing screw. DEFLECTION YOKE DEFLECTION YOKE SCREW MAGNET SCREW 3-3: STATIC CONVERGENCE NOTE Adjust after performing adjustments in section 3-2. 1. Receive the crosshatch pattern from the color bar generator. 2. Combine red and blue of the 3 color crosshatch pattern on the center of the screen by adjusting the pair of 4 pole magnets. 3. Combine red/blue (magenta) and green by adjusting the pair of 6 pole magnets. 3-4: DYNAMIC CONVERGENCE NOTE Adjust after performing adjustments in section 3-3. 1. Adjust the differences around the screen by moving the deflection yoke upward/downward and right/left. (Refer to Fig. 3-2-a) 2. Insert three wedges between the deflection yoke and CRT funnel to fix the deflection yoke. (Refer to Fig. 3-2-b) RGB R G B RGB
R G B RIGHT/LEFT SLANT
UPWARD/DOWNWARD SLANT
Fig. 3-2-a
WEDGE
WEDGE
WEDGE WEDGE POSITION Fig. 3-2-b
PURITY MAGNETS 6 POLE MAGNETS 4 POLE MAGNETS Fig. 3-1
D-4
|
|
|
> |
|