|
Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
I would not plug this machine in without finding a manual like this. In addition to setup and normal operating instructions, it has troubleshooting flowcharts, diagrammed mechanical adjustments, and schematics to beat the band. The tech I hand it to would be thrilled to find solder side PCB diagrams with component outlines superimposed, pinouts for every IC chip, and line drawings of transistors, with labeled legs.
As for printing quality, this may be a copy of a copy, but even the finest print when enlarged is very legible. There is a bit of grayed print over a few pages, as if a wet page were placed over it, but the print is still very legible. If you could borrow an original manual and get it printed and bound for 4 to 6 times the cost, you could get better quality. In that case you wouldn't be here. For price, utility, and availability I am rating this manual highly.
;
I received the Manual in a timely manner and it was exactly what I needed.
This is a perfect copy of the Service Manual, The quality is great. I am very
happy. Thank you
;
exactly as they say. Within 24 hours the link to the pages and offcourse it was the right service manual. Super and thanks
;
The manual was exact the thing that was promised. My old car stereo is working again thanks to the information supplied.
;
I PURHASED THIS PRODUCT BECAUSE I WAS HAVING PROBLEMS WITH MY CDR20 HARMAN KARDON RECORDER. WHICH I PURCHASED NEW 12 YEARS AGO. AFTER REVIEWING THE MANUAL, I WAS ABLE TO ADJUST THE TENSIONER IN THE SYSTEM. WORKS LIKE A CHAMP!.
SAVED ME AT LEAST 100.00 WHICH WAS WHAT A SERVICE REPAIR STATION WANTED. GREAT MANUAL EASY TO READ. SPECIALLY AFTER I PRINTED THE PAGES WHICH DEALT WITH MY RECORDER. THANKS A LOT!!!!!!!!
ELECTRICAL ADJUSTMENTS
3. PURITY AND CONVERGENCE ADJUSTMENTS
NOTE 1. Turn the unit on and let it warm up for at least 30 minutes before performing the following adjustments. 2. Place the CRT surface facing east or west to reduce the terrestrial magnetism. 3. Turn ON the unit and demagnetize with a Degauss Coil. 3-1: STATIC CONVERGENCE (ROUGH ADJUSTMENT) 1. Tighten the screw for the magnet. Refer to the adjusted CRT for the position. (Refer to Fig. 3-1) If the deflection yoke and magnet are in one body, untighten the screw for the body. 2. Receive the green raster pattern from the color bar generator. 3. Slide the deflection yoke until it touches the funnel side of the CRT. 4. Adjust center of screen to green, with red and blue on the sides, using the pair of purity magnets. 5. Switch the color bar generator from the green raster pattern to the crosshatch pattern. 6. Combine red and blue of the 3 color crosshatch pattern on the center of the screen by adjusting the pair of 4 pole magnets. 7. Combine red/blue (magenta) and green by adjusting the pair of 6 pole magnets. 8. Adjust the crosshatch pattern to change to white by repeating steps 6 and 7. 3-2: PURITY NOTE Adjust after performing adjustments in section 3-1. 1. Receive the green raster pattern from color bar generator. 2. Adjust the pair of purity magnets to center the color on the screen. Adjust the pair of purity magnets so the color at the ends are equally wide. 3. Move the deflection yoke backward (to neck side) slowly, and stop it at the position when the whole screen is green. 4. Confirm red and blue color. 5. Adjust the slant of the deflection yoke while watching the screen, then tighten the fixing screw. DEFLECTION YOKE DEFLECTION YOKE SCREW MAGNET SCREW 3-3: STATIC CONVERGENCE NOTE Adjust after performing adjustments in section 3-2. 1. Receive the crosshatch pattern from the color bar generator. 2. Combine red and blue of the 3 color crosshatch pattern on the center of the screen by adjusting the pair of 4 pole magnets. 3. Combine red/blue (magenta) and green by adjusting the pair of 6 pole magnets. 3-4: DYNAMIC CONVERGENCE NOTE Adjust after performing adjustments in section 3-3. 1. Adjust the differences around the screen by moving the deflection yoke upward/downward and right/left. (Refer to Fig. 3-2-a) 2. Insert three wedges between the deflection yoke and CRT funnel to fix the deflection yoke. (Refer to Fig. 3-2-b) RGB RGB R G B
R
G B UPWARD/DOWNWARD SLANT RIGHT/LEFT SLANT Fig. 3-2-a
WEDGE
WEDGE
WEDGE WEDGE POSITION Fig. 3-2-b
PURITY MAGNETS 6 POLE MAGNETS 4 POLE MAGNETS Fig. 3-1
D-3
|
|
|
> |
|