Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Manual acquired with good resolution, complete in all its pages, very good policy of the folder where are saved all products purchased.
 ;
Service manual very complete and clear. It was very helpfull for my work.
 ;
This is the 2nd time I download manuals from this website and I can say it's what I was expecting. It contains schematic, layout (decent quality), short description, parts and dissasembly instructions. I recomend it for anyone who wants to repair/modify this device.
 ;
Very useful Service Manual! With it I was able to identify the damaged pots in my old amplifier, purchase the adequate replacements and make myself the repair.
I have again my old amplifier, still a very good one that I will keep for as many years as I can!
Thanks to Owner Manuals!
 ;
Good price for the manual and easy to locate on the site and download. Plus, just like the original. Thanks a lot.
20AG1-SS
DESCRIPTION OF SCHEMATIC DIAGRAM
SAFETY NOTES:
1. DISCONNECT THE AC PLUG FROM THE AC OUTLET BEFORE REPLACING PARTS. 2. SEMICONDUCTOR HEAT SINKS SHOULD BE REGARDED AS POTENTIAL SHOCK HAZARDS WHEN THE CHASSIS IS OPERATING.
NOTES:
1. The unit of resistance "ohm" is omitted. (K = 1000 ohms, M = Mega ohm). 2. All resistors are 1/10 watt, unless otherwise noted. 3. All capacitors are �F, unless otherwise noted. (P = �� F).
IMPORTANT SAFETY NOTICE:
PARTS MARKED WITH " å " ( ) ARE IMPOTANT FOR MAINTAINING THE SAFETY OF THE SET. BE SURE TO REPLACE THESE PARTS WITH SPECIFIED ONES FOR MAINTAINING THE SAFETY AND PERFORMANCE OF THE SET.
VOLTAGE MEASUREMENT CONDITIONS:
1. Voltages in parenthesis measured with no signal. 2. Voltages without parenthesis measured with 3mV B & W or Colour signal. 3. All the voltages in each point are measured with VTVM.
SERVICE PRECAUTION:
THE AREA ENCLOSED BY THIS LINE ( �� - ��) IS DIRECTLY CONNECTED WITH AC MAINS VOLTAGE. WHEN SERVICING THE AREA, CONNECT AN ISOLATING TRANSFORMER BETWEEN TV RECEIVER AND AC LINE TO ELIMINATE HAZARD OF ELECTRIC SHOCK.
WAVEFORM MEASUREMENT CONDITIONS:
1. The colour bar generator signal of 2.0V peak applied at of Base Video Buffer Amp. Q252. 2. Approximately 4V AGC bias .
25
|
|
 |
> |
|