Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
A site where discontinualed schematic diagrams and back dated information can be found on discontinued radios tv's and any electronic equipment can be found. Newer manuals either Service and operating manuals. Radio amateurs should find this site a great source for ham radio equipment manuals. I will return to this site should I need information on any electrical equipment. priced easy to download in a PDF format and print pages need to undertake the repair.
 ;
Quality scan of the original. All the detail necessary to troubleshoot, repair and adjust the unit. I'm sure I will be downloading more manuals in the future as the need arises.
 ;
Exactly as described, a Service Manual complete with the schematics and PCB layout delivered in a timely manner. Many thanks for the great service.
 ;
some of the writing is a bit blur but the part in the schmatic was great and i have fixed the machine thanks
 ;
Well.. I'd searched for this manual and although I found many copies online I was pleased to find your website with a well balanced pricing system and easy to search and follow links. That together with the very quick response time was just what I was looking for.. being a very impatient tech.. ;-) I had the service manual in front of me within a short time.
Bookmarked.. and you can bet I will always come here first for my service & user manuals..
best regards
Ed(Tony) Foley
G7WHK
CONVERGENCE ADJUSTMENT
NO. Adjustment part 1 CONVERGENC ADJ. (To be done after the purity adjustment.) Adjusting procedure and conditions 1. Receive the "Crosshatch Pattern" signal. 2. Using the remote controller, call NORMAL mode. Static convergence 1. Turn the 4-pole magnet to a proper opening angle in order to superpose the blue and red colours. 2. Turn the 6-pole magnet to a proper opening angle in order to superpose the green colour over the blue and red colours. Dynamic convergence 1. Adjust the convergence on the fringes of the screen in the following steps. a) Fig. 5-1: Drive the wedge at point "a" and swing the deflection coil upward. b) Fig. 5-2: Drive the wedge at points "b" and "c" and swing the deflection coil downward. c) Fig. 5-3: Drive the "c" wedge deeper and swing the deflection coil rightward. d) Fig. 5-4: Drive the "b" wedge deeper and swing the deflection coil leftward. 2. Fix all the wedges on the CRT and apply glass tape over them. 3. Apply lacquer to the deflection yoke lock screw, magnet unit (purity, 4-pole, 6-pole magnets) and magnet unit lock screw. Finally received the Red-only and Blue-only signals to make sure there is no other colours on the screen.
About 100° Lacquer Wedge "b" Wedge "c" About 100°
CRT CUT-OFF, BACKGROUND AND SUB-CONTRAST ADJUSTMENT
NO. Adjustment part 1
B G R
Waveform and others
BGR
Adjusting procedure and conditions 1. Switch TV to VIDEO mode, BLUE BACK OFF with NO VIDEO signal. 2. Press R/C to set Picture Normal condition. 3. Connect the oscilloscope to Red OUT from IC801.(TP852) Range Sweep : 1 V/Div (DC) : 5 msec/Div
0
Waveform and others
3.0Vdc
CRT CUTOFF ADJUSTMENT (I2C BUS CONTROL)
Fig. 5-1
RGB R G B
1V
4. Adjust SCREEN VR, so that the tip of signal reach 3.0 +0.1 Vdc. 2 SUBBRIGHTNESS ADJUSMENT (I2C BUS CONTROL) 1. Call "SUB-BRI" in service mode. (Receive Crosshatch pattern with 5 black level windows) 2. Adjust the "SUB BRIGHT" bus data in order that the line 1, 2 and 3 have the same darkness wherelse line 4 is slightly brighter than line 1, 2 and 3 and finally line 5 will be the brighter than line 4.
Fig. 6
Fig. 5-2 RGB
B G R
12345
1, 2 and 3 are in same black level. Fig. 7 Refer to Page 7. * 7500°K X : 0.300 Y : 0.310 * 12,300°K X : 0.272 Y : 0.275
Fig. 5-3
R G B BGR
3
WHITE BALANCE SERVICE MODE ADJ. (I2C BUS CONTROL)
1. Receive the "Monoscope Pattern" signal. 2. Press R/C to set Picture NORMAL condition. 3. Connect the DC miliammeter between TP602 (-) and TP603 (+). 4. Check Beam current should be around 1,100 µA. 5. Set it to service mode and adjust the " WPG" (White Point-G), "WPB" (White Point-B) data to have a colour temperature of 12,300°K or 7500°K (white). * Note . 6. When changed back to non-service mode, adjust the Contrast & Brightness control to have a beam current of 200µA. If the colour temperature is not at 12,300°K or 7500°K go back to No. 1. Note: This adjustment must be done after warming up the unit for 30 minutes or longer with a beam current over 700µA). * ADJUST DRI-GC/GW, DR-BC/BW AS FOLLOWING DATA, AFTER FIHISHING DRI-GS AND DRI-BS. DRI-GC/GW DATA: "DRI-GS"-7 DATA DRI-RC:27 DRI-BW DATA: "DRI-BS" -5 DATA DRI-BC=DRI-BS
Fig. 5-4
Wedge "a"
(MINOLTA COLOUR ANALYZER CA-100) *Note: Above Data can be UP/ DOWN by Volume key.
9
Fig. 5-5
4-pole magnet 6-pole magnet CRT neck
4
Lacquer Purity magnet
20cm
Maximum beam check
Fig. 5-6
1. Receive the "Monoscope Pattern" signal. 2. Press R/C to set Picture NORMAL condition. 3. Connect the DC miliammeter between TP603 (+) and TP602 (�). (Full Scale: 3 mA Range) 4. Beam current must be within 1,100 ±100 µA.
20A1/2, 20AG1/2 21A1/2, 21AG1/2
9-1
9-2
|
|
 |
> |
|