I had been looking everywhere for a proper service manual for this VCR. Everywhere else that has this available for download has a very light version. This is the full service manual with all aspects that would interest anyone looking for the service manual for the AIWA HV-MX100 Worldwide VHS VCR. Great quality (as always). A winner hands down. Best Quality.
 ;
Top quality manual. Covers all aspects you'd expect in a top quality service manual for this Panasonic VHS VCR. The manual resolution is high. Another top quality manual from the only site worth downloading manuals from! If you're looking for a manual for the PV-9662 VHS VCR, this is the one you'll want to get!
 ;
complete part-lists and pcb layout, schematic diagram is good enlargable,
 ;
Excellent, fast delivery, excellent product. Good luck!
 ;
This manual is for the usa model only. But it is clear
, accurate and comprehensive, including board layouts and schematics.
I found it extremely useful for my mitsubishi dp-86da, but the same diagram would also work for the realistic lab5000 and hi fi 80. Thanks.
PURITY CONVERGENCE ADJUSTMENT
a b
B (2) Degauss CRT. Maintain magnet after the purity mode. G
NO POINT ADJUSTMENT CONDITION / PROCEDURE WAVEFORM OR OTHERS PURITY ADJ. GREEN ONLY Adjust 1 CONVERGENCE (1) Receive the "Crosshatch Pattern" signal. B G R
beam current to over 700µA ADJ (To be done (2) Using the remote controller, call NORMAL
at zero magnetic field and keep the static adjustment.) (Static convergence) R convergence roughly adjusted. (1) Turn the 4 pole magnet to a proper opening Fig. 1-1 through microscope. Adjust the landings to colours.
R G B
(3) Observe points a,b, as shown Fig.1 1 angle in order to superpose the blue and red Fig. a
A rank requirement. (2) Turn the 6 pole magnet to a proper opening
A Tightening torque : 108N 20N ( 11Kgf ± 2Kgf (Dynamic convergence ) A=B (6) Make sure CRT corners landing meet A (1) Adjust convergence on fringes of the
B sheet to correct it. a) Fig. a : G
(4) Orient raster rotation 0 eastward. angle in order to superpose the green colour R
G (5) Tighten up deflection coil screws. over the blue and red colours. B
Fig. b
rank requirements. If not, stick magnet screen in the following steps. R G B
B
Note : This adjustment must be done after Drive the wedge at point a " and swing Fig. 1-2 Rank A (On the right of CRT) R
warming up unit for 30 minutes or longer the deflection coil upward. with a beam current over 700µA. b) Fig. b :
Drive the wedge at point b " and Fig. c
G R change. c) Fig. c :
* For following colours press R/C RGB key to swing the deflection coil downward. A B G R
B Drive the c " wedge deeper and B
A=B
swing the deflection coil rightward. d) Fig. d :
1-3 Rank A (On the left of CRT) Drive b " wedge deeper and swing the Fig. d ONLY
RED GREEN BLUE
deflection coil leftward.
Wedge "a" (2) Fix all wedges on the CRT and apply glass
9
tape over them.
(3) Apply lacquer to the deflection yoke lock screw, magnet unit (purity, 4 pole, 6 pole
* Press R/C RGB key for 1 second in NORMAL MODE, Signal-colour the colour will change to RGB screen cleared mono colour mode. About About
100 Deg
magnets) and magnet unit lock screw.
Lacquer
Finally received the Red and Blue only signals to make sure there is no other colours on the screen. 6-Pole Magnet. CRT NECK
100 Deg
"b" Wedge "c"
(21") 20cm Purity Magnet Lacquer 4-Pole Magnet
20GT-30 21GT-30
|
|
 |
> |
|