It's great to be able to obtain a precious technical information for a real old equipment. The one I got helps me a lot in the area of wiring diagram to repair my antique. PDF gave me clear enough information to find out thr details. Thanks for giving me the oppotunity to be able to access to almost vanished informations.
Good quality for the scan, complete, but as usual for Tascam, not so comprehensive !
Text excerpt from page 10 (click to view)
21HM-10F
� GEOMETRY ADJUSTMENT PROCEDURE
To adjust the geometry, follow the procedure outlined below: 1.Tune the set into a Philips test pattern. 2.Enter the service mode as described on page 6. 3.Use the channel up or channel down buttons to enter the desired mode 4.Use the volume buttons to achieve correct setting. 5.When adjustments are complete, use the standby button to turn off the set. The adjustment values will be stored at this point.
V-LIN Adjust the vertical linearity control so that the picture centring is as shown in figure 5.
Fig. 5 V-AMP Adjust the vertical amplitude control so that the picture overscans as shown in figure 6.
Fig. 6 V-CENT Adjust the vertical centring control so that the picture is centred as shown in figure 7.
Fig. 7 H-CENT Adjust the horizontal centring control so that the picture is centred as shown in figure 8.