Happy to find finally a schematic for this amplifier. The schematic is of good quality, the pcb layout is useless: all is black. Never the less, it is very easy to find the components on the board using the schematics.
 ;
Hard to find manual was ready the next day. Scans were very legible (including schematics). All the essential parts of the service manual were present (adjustment procedure, schematics, and parts list). It would have been nice if the rest of the manual was included (disassembly procedure, theory of operation, etc.).
 ;
The Service Manual for the Kenwood KR-V55R provided by owner-manuals.com was as described/advertised. The contents provided the necessary information to effect a diagnosis of the unit. The schematics above all else was instrumental in tracing the the signal flow from component to component.
 ;
This manual was the factory original. Excellent value and contained all the details I needed. Easy dowwnload provided the information when I needed it.
 ;
Impeccable, document très complet. Perfect, i get all i need. All schematic are correct. Thanks
ELECTRICAL ADJUSTMENTS
2-6: FOCUS 1. Receive a 70dB monoscope pattern. 2. Turn the Focus Volume fully counterclockwise once. 3. Adjust the Focus Volume until picture is distinct. 2-7: HORIZONTAL POSITION 1. Receive the monoscope pattern from the Pattern Generator. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (08) on the remote control to select "H POSI (50)". 4. Press the VOL. +/- button on the remote control until the SHIFT quantity of the OVER SCAN on right and left becomes minimum. 5. Receive the monoscope pattern of NTSC. (Audio Video Input) 6. Using the remote control, set the brightness and contrast to normal position. 7. Activate the adjustment mode display of Fig. 1-1 and press the channel button (39) on the remote control to select "H POSI (60)". 8. Press the VOL. +/- button on the remote control until the SHIFT quantity of the OVER SCAN on right and left becomes minimum. 2-8: VERTICAL SIZE 1. Receive the monoscope pattern from the Pattern Generator. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (11) on the remote control to select "V SIZE (50)". 4. Adjust by using the VOL. +/- button on the remote control so that the Up/Down OVER SCAN Quantity becomes equal to the Right/Left OVER SCAN Quantity. 5. Receive a broadcast and check if the picture is normal. 6. Receive the monoscope pattern of NTSC. (Audio Video Input) 7. Using the remote control, set the brightness and contrast to normal position. 8. Activate the adjustment mode display of Fig. 1-1 and press the channel button (12) on the remote control to select "V SIZE (60)". 9. Adjust by using the VOL. +/- button on the remote control so that the Up/Down OVER SCAN Quantity becomes equal to the Right/Left OVER SCAN Quantity. 2-9: VERTICAL POSITION/VERTICAL LINEARITY 1. Receive the monoscope pattern from the Pattern Generator. 2. Using the remote control, set the brightness and contrast to normal position. 3. Adjust the VR401 until the horizontal line becomes fit to the notch of the shadow mask. 4. Adjust the VR420 until the SHIFT quantity of the OVER SCAN on upside and downside becomes minimum. 90% 100% 2-10: BRIGHT CENT 1. Receive the PAL black pattern*. (RF Input) 2. Using the remote control, set the brightness and contrast to normal position. 3. Place the set with Aging Test for more than 15 minutes. 4. Activate the adjustment mode display of Fig. 1-1 and press the channel button (17) on the remote control to select "BRIGHT CENT". 5. Press the VOL. +/- button on the remote control until the screen begin to shine. 6 Receive the PAL black pattern*. (Audio Video Input) 7. Set to the AV mode. Then perform the above adjustments 2~5. *The Black Pattern means the whole black raster signal. Select the "RASTER" of the pattern generator, set to the OFF position for each R, G and B. 2-11: CONTRAST CENT 1. Activate the adjustment mode display of Fig. 1-1 and press the channel button (22) on the remote control to select "CONTRAST CENT". 2. Press the VOL. +/- button on the remote control until the contrast step No. becomes "35". 3. Receive a broadcast and check if the picture is normal. 4. Set to the AV mode. Then perform the above adjustments 1~3. 2-12: COLOR CENT 1. Receive the PAL color bar pattern. (RF Input) 2. Using the remote control, set the brightness, contrast and color to normal position. 3. Connect the oscilloscope to TP022. 4. Activate the adjustment mode display of Fig. 1-1 and press the channel button (25) on the remote control to select "COLOR CENT". 5. Adjust the VOLTS RANGE VARIABLE knob of the oscilloscope until the range between white 100% and 0% is set to 5 scales on the screen of the oscilloscope. 6. Press the VOL. +/- button on the remote control until the red color level is adjusted to 90 ± 10% of the white level. (Refer to Fig. 2-1) 7. Receive the PAL color bar pattern. (Audio Video Input) 8. Set to the AV mode. Then perform the above adjustments 2~6.
Fig. 2-1
D-2
|
|
 |
> |
|