MACKIE HR824 26 pages English-only Service Manual contains:
1) HR824 technical overview with the description of front and rear panel switches.
2) HR824 specs
3) Block Diagram
4) Wiring Diagram
5) Packaging management
6) Spare part & final assembly list (for PCB rev A and B) + exploded view
7) Test Procedures (where, how to measure voltage...) including Test Point diagram on the PCB.
8) IC and Transistor charts.
Excellent guide: very clear, good scan quality enabling us to print readable diagram :-)
Note:
Mackie HR824 make extensive use of surface mount devices (SMD). Service on the HR824 must
only be undertaken by experienced service technicians with the right tools, experience and patience to perform surface mount rework when needed.
 ;
This Service manual is very well scanned and its clean to read, no any anti-theft words that un-english could understand. I got my CCD600 working with this manual and it´s clear shematics :)
 ;
I was very pleased with the service provided and was surprised at how good the quality was of the manual. I thought it may be a third generation copy or so, but it is as good as the websites that charge 3 times this much. I repair some electronics for family and friends without charge, so this is perfect for me. Thank you very much.
ELECTRICAL ADJUSTMENTS
3. PURITY AND CONVERGENCE ADJUSTMENTS
NOTE 1. Turn the unit on and let it warm up for at least 30 minutes before performing the following adjustments. 2. Place the CRT surface facing east or west to reduce the terrestrial magnetism. 3. Turn ON the unit and demagnetize with a Degauss Coil. 3-1: STATIC CONVERGENCE (ROUGH ADJUSTMENT) 1. Tighten the screw for the magnet. Refer to the adjusted CRT for the position. (Refer to Fig. 3-1) If the deflection yoke and magnet are in one body, untighten the screw for the body. 2. Receive the green raster pattern from the color bar generator. 3. Slide the deflection yoke until it touches the funnel side of the CRT. 4. Adjust center of screen to green, with red and blue on the sides, using the pair of purity magnets. 5. Switch the color bar generator from the green raster pattern to the crosshatch pattern. 6. Combine red and blue of the 3 color crosshatch pattern on the center of the screen by adjusting the pair of 4 pole magnets. 7. Combine red/blue (magenta) and green by adjusting the pair of 6 pole magnets. 8. Adjust the crosshatch pattern to change to white by repeating steps 6 and 7. 3-2: PURITY NOTE Adjust after performing adjustments in section 3-1. 1. Receive the green raster pattern from color bar generator. 2. Adjust the pair of purity magnets to center the color on the screen. Adjust the pair of purity magnets so the color at the ends are equally wide. 3. Move the deflection yoke backward (to neck side) slowly, and stop it at the position when the whole screen is green. 4. Confirm red and blue colors. 5. Adjust the slant of the deflection yoke while watching the screen, then tighten the fixing screw. DEFLECTION YOKE DEFLECTION YOKE SCREW MAGNET SCREW 3-3: STATIC CONVERGENCE NOTE Adjust after performing adjustments in section 3-2. 1. Receive the crosshatch pattern from the color bar generator. 2. Combine red and blue of the 3 color crosshatch pattern on the center of the screen by adjusting the pair of 4 pole magnets. 3. Combine red/blue (magenta) and green by adjusting the pair of 6 pole magnets. 3-4: DYNAMIC CONVERGENCE NOTE Adjust after performing adjustments in section 3-3. 1. Adjust the differences around the screen by moving the deflection yoke upward/downward and right/left. (Refer to Fig. 3-2-a) 2. Insert three wedges between the deflection yoke and CRT funnel to fix the deflection yoke. (Refer to Fig. 3-2-b) RGB R G B RGB
R G B RIGHT/LEFT SLANT
UPWARD/DOWNWARD SLANT
Fig. 3-2-a
WEDGE
WEDGE
WEDGE WEDGE POSITION Fig. 3-2-b
PURITY MAGNETS 6 POLE MAGNETS 4 POLE MAGNETS Fig. 3-1
D-4
|
|
 |
> |
|