Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Original well scanned manual. Got the job done. Microwave problem found & corrected. For $5 and a new magnitron from ebay, it was a cheap and good the first shot fix. Electrical schematics allowed me to mage sure every thing else was ok before cutting and order for parts. Hard to live without.
 ;
I was very skeptical of this website, I have never downloaded manuals before. I put it on the AMEX and payed through Paypal to ensure protection. I got the manual exactly as described and now I can replace the filter capacitor for this amp. Great Price, others selling for 12.99 or more and this is the same manual. I will search out this website for other manuals. Thank you
 ;
Manual was reasonably easy to follow. I am not an engineer or know much about electronics but with the manuals help I was able to figure out the problem, identify the part required for the repair. Replacement part cost around $30. Whilst replacing the part I was telling myself, "this aint gonna work cos it seems far too easy". Took about 15 minutes to do and my plasma TV works a treat. Would never have been able to do this without the service manual.
 ;
It is OK, this manual help me to repair my dynacord
 ;
Good manual. Even it is an old printed manual, it is well scanned and complete, with all drawings, schematics and parts list. Very good return for the cost.
ELECTRICAL ADJUSTMENTS
2-6: FOCUS 1. Receive a 70dB monoscope pattern. 2. Turn the Focus Volume fully counterclockwise once. 3. Adjust the Focus Volume until picture is distinct. 2-7: HORIZONTAL POSITION 1. Receive the monoscope pattern from the Pattern Generator. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (08) on the remote control to select "H POSI (50)". 4. Press the VOL. +/- button on the remote control until the SHIFT quantity of the OVER SCAN on right and left becomes minimum. 5. Receive the monoscope pattern of NTSC. (Audio Video Input) 6. Using the remote control, set the brightness and contrast to normal position. 7. Activate the adjustment mode display of Fig. 1-1 and press the channel button (39) on the remote control to select "H POSI (60)". 8. Press the VOL. +/- button on the remote control until the SHIFT quantity of the OVER SCAN on right and left becomes minimum. 2-8: VERTICAL SIZE 1. Receive the monoscope pattern from the Pattern Generator. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (11) on the remote control to select "V SIZE (50)". 4. Adjust by using the VOL. +/- button on the remote control so that the Up/Down OVER SCAN Quantity becomes equal to the Right/Left OVER SCAN Quantity. 5. Receive a broadcast and check if the picture is normal. 6. Receive the monoscope pattern of NTSC. (Audio Video Input) 7. Using the remote control, set the brightness and contrast to normal position. 8. Activate the adjustment mode display of Fig. 1-1 and press the channel button (12) on the remote control to select "V SIZE (60)". 9. Adjust by using the VOL. +/- button on the remote control so that the Up/Down OVER SCAN Quantity becomes equal to the Right/Left OVER SCAN Quantity. 2-9: VERTICAL POSITION/VERTICAL LINEARITY 1. Receive the monoscope pattern from the Pattern Generator. 2. Using the remote control, set the brightness and contrast to normal position. 3. Adjust the VR401 until the horizontal line becomes fit to the notch of the shadow mask. 4. Adjust the VR420 until the SHIFT quantity of the OVER SCAN on upside and downside becomes minimum. 90% 100% 2-10: BRIGHT CENT 1. Receive the PAL black pattern*. (RF Input) 2. Using the remote control, set the brightness and contrast to normal position. 3. Place the set with Aging Test for more than 15 minutes. 4. Activate the adjustment mode display of Fig. 1-1 and press the channel button (17) on the remote control to select "BRIGHT CENT". 5. Press the VOL. +/- button on the remote control until the screen begin to shine. 6 Receive the PAL black pattern*. (Audio Video Input) 7. Set to the AV mode. Then perform the above adjustments 2~5. *The Black Pattern means the whole black raster signal. Select the "RASTER" of the pattern generator, set to the OFF position for each R, G and B. 2-11: CONTRAST CENT 1. Activate the adjustment mode display of Fig. 1-1 and press the channel button (22) on the remote control to select "CONTRAST CENT". 2. Press the VOL. +/- button on the remote control until the contrast step No. becomes "40". 3. Receive a broadcast and check if the picture is normal. 4. Set to the AV mode. Then perform the above adjustments 1~3. 2-12: COLOR CENT 1. Receive the PAL color bar pattern. (RF Input) 2. Using the remote control, set the brightness, contrast and color to normal position. 3. Connect the oscilloscope to TP022. 4. Activate the adjustment mode display of Fig. 1-1 and press the channel button (25) on the remote control to select "COLOR CENT". 5. Adjust the VOLTS RANGE VARIABLE knob of the oscilloscope until the range between white 100% and 0% is set to 5 scales on the screen of the oscilloscope. 6. Press the VOL. +/- button on the remote control until the red color level is adjusted to 90 ± 10% of the white level. (Refer to Fig. 2-1) 7. Receive the PAL color bar pattern. (Audio Video Input) 8. Set to the AV mode. Then perform the above adjustments 2~6.
Fig. 2-1
D-2
|
|
 |
> |
|