Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Excellent just what I needed to replace the electrolytic caps and make this old gem a beauty again. Was as scan of the original photocopied service manual.
 ;
It was helpful to get schematic with waveforms in important points and lot of service information. Manual is good quality, fast delivered. Of course it is hardcopy of paper one with all its disadvantages.
 ;
I want to give you a real heads-up for your desire to enable such people as I to acquire the information I need to maintain the older types of equipment such as this Akai HXA351W. You do a swell job with all the processes you have to perform so I can have a legible, thus usable
document which does not send me crazy trying to figure out the blurry text of a bad copy.
Very well done, Thomas.
 ;
This manual is very well presented and after printing out looks about as close to an original as I think you can get. The quality is second to none.
The content of the manual is comprehensive and I think it would be well suited to an audio repair professional which I'm not but I did find it very informative and helpful.
The cost of the manual is more than covered by the money I'll save when I change the keep memory battery now I have the relavant info.
Very pleased with my purchase and can recommend it wholeheartedly as I can other manuals I've downloaded from this site.
Regards
Limey Alex
 ;
Complete manual including mechanical part in good pdf quality. Shaded greys of the pcb due to pdf not perfect but usable.
25L-M100/180/S100/180 CL25M10,CL25S18
MTS ADJUSTMENT
(Only for 25L-S100/180, CL25S18)
MTS Level Adjustment
1. Feed the following monaural signal to pin (14) of IC3001. Monaural signal : 300Hz, 245mVrms 2. Connect the rms voltmeter to pin (39) of IC3001. 3. Enter the service mode and select the service adjustment "M01". 4. Adjust the data so that the rms voltmeter reads. 490 ±10mVrms.
MTS VCO Adjustment
1. Keep the unit in no-signal state. 2. Connect the frequency counter to pin (39) of IC3001. 3. Connect a capacitor (100µF, 50V) in between positive(+) side of C3005 and ground. 4. Enter the service mode and select the service adjustment "M02" 5. Adjust the data so that the frequency counter reads. 62.94 ±0.75kHz.
Filter Adjustment
1. Feed the following stereo pilot signal to pin (14) of IC3001 . Stereo pilot signal: 9.4kHz, 600mVrms. 2. Enter the service mode and select the service adjustment "M03". 3. Adjust the data at the point where "OK" appears on the screen. The "OK" represents the approximate center of the adjustable range of the data.
Separation Adjustment
1. Connect the rms voltmeter to pin (39) of IC3001. 2. Receive the following composite stereo signal 1. Composite stereo signal: 30% modulation, left channel only, noise reduction on, 300Hz 3. Enter the service mode and select the service adjustment "M04". 4. Adjust the data until the AC voltage reading of the rms voltmeter is minimum. 5. Receive the following composite stereo signal 2. Stereo signal: 30% modulation, left channel only, noise reduction on, 3kHz 6. Enter the service mode and select the service adjustment "M05". 7. Adjust the data until the AC voltage reading of the rms voltmeter is minimum. 8. Take the above steps 1 thru 8 again for fine adjustment.