Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Very quick and easy website to use and fast download of manual, quality of manual is excellent and will be pleased to use this service again in the future, thanks so much!
 ;
Easy and secure way to get a complete service manual of a vintage hifi component. Only some parts of the print copy are dificult to read. Nice price!
 ;
The manual is an excellent reproduction with complete schematics, made troubleshooting and repair a simple process.
 ;
Up to now you are the BEST! Prompt-efficient and so reasonable ! I have been after SONY service manual for quite some time !Thank you very much ! I can recomend your service to
all my collegagues ! V.Bergfield .
 ;
This is a very good quality print (scan) of the original SONY service manual. The original from Sony is on very thin paper. Nevertheless it is very clear and sharp and excellent readable. I'm very satisfied to have now this rare document. I've looking for it many years (infrequent). It contains very detailed circuit diagrams, exploded views, part lists, PCB view with good readable connection lines. Very recommended.
WARNING: BEFORE SERVICING THIS CHASSIS, READ THE �X-RAY RADIATION PRECAUTION�, �SAFETY PRECAUTION� AND �PRODUCT SAFETY NOTICE� ON PAGE 3 OF THIS MANUAL.
SET-UP ADJUSTMENT
s The following adjustments should be made when a complete realignment is required or a new picture tube is installed. Perform the adjustments in order as follows : 1. Color Purity 2. Convergence 3. White Balance Note: The PURITY/CONVERGENCE MAGNET assembly and rubber wedges need mechanical positioning. Refer to figure 1. Mounting position of the purity magnet assembly should fit to same position as old one because slightly difference to the position depend on a kind of tube.
*
There are no adjustment of purity and convergence in some picture tube (Unified with purity magnet) 5. Remove the Rubber Wedges. 6. Rotate and spread the tabs of the purity magnet (See figure 2.) around the neck of the picture tube until the green belt is in the center of the screen. At the same time, enter the raster vertically. 7. Slowly move the yoke forward or backward until a uniform green screen is obtained. Tighten the clamp screw of the yoke temporarily. 8. Check the purity of the red and blue raster.
SPECIFIC INFORMATIONS GENERAL ADJUSTMENTS
COLOR PURITY ADJUSTMENT NOTE : Before attempting any purity adjustments, the receiver should be operated for at least fifteen minutes. 1. Demagnetize the picture tube and cabinet using a degaussing coil. 2. Set the brightness and contrast to maximum. 3. Use a green raster from among the built-in test signals. 4. Loosen the clamp screw holding the yoke and slide the yoke backward or forward to provide vertical green belt (zone) in the picture screen.
DEFLECTION YOKE
TEMPORARY MOUNTING
29.1mm(28", 29") 25mm(25") 19mm(19", 20", 21") 14mm(13", 14")
RUBBER WEDGE
ADHESIVE PURITY/ CONVERGENCE MAGNET ASS'Y
DEFLECTION YOKE
GLASS CLOTH TAPES
Figure 1.