TUD3000W2 Quantity: 1
$4.99
» View Details
AFG 6491-B Quantity: 1
$4.99
» View Details
AFG 819/2 Quantity: 1
$4.99
» View Details
DV-515/WYW/SP Quantity: 1
$4.99
» View Details
MDR-V600 Quantity: 1
$4.99
» View Details
KTRC22KMBT05 Quantity: 1
$4.99
» View Details
TGZ 3403 WS Quantity: 1
$4.99
» View Details
AKZ 228/NB Quantity: 1
$4.99
» View Details
LGV4434AN0 Quantity: 1
$4.99
» View Details
SV8300 Quantity: 1
$4.99
» View Details
SLCT710EG Quantity: 1
$4.99
» View Details
GSI 4865/3 TW-IN Quantity: 1
$4.99
» View Details
AKR 812 IX Quantity: 1
$4.99
» View Details
DVT231 Quantity: 1
$4.99
» View Details
WMF100 Quantity: 1
$4.99
» View Details
KUDB03CTBS0 Quantity: 1
$4.99
» View Details
ARC 7495/IS Quantity: 1
$4.99
» View Details
KCMS135SWH0 Quantity: 1
$4.99
» View Details
RF196LXMQ2 Quantity: 1
$4.99
» View Details
DV-525/KC Quantity: 1
$4.99
» View Details
AW1015L Quantity: 1
$4.99
» View Details
346.551 5/10553 Quantity: 1
$4.99
» View Details
RF360BXVM0 Quantity: 1
$4.99
» View Details
CWC121AM Quantity: 1
$4.99
» View Details
GS6SHANLQ10 Quantity: 1
$4.99
» View Details
LA5430XTW1 Quantity: 1
$4.99
» View Details
HTDDW740 Quantity: 1
$4.99
» View Details
VSX-D810S-G Quantity: 1
$4.99
» View Details
BOGZRA SW Quantity: 1
$4.99
» View Details
Sub-Total: $144.71
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Categories
Information
Featured Product
Home >> PHILIPS >> 55P8241 Service Manual
 
 29 item(s) in your cart 

PHILIPS 55P8241
Service Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Contains Circuit Diagrams
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of PHILIPS 55P8241 Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages:

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 RS-1500US VOLUME 2 TECHNICS Service Manual by Jozsef Hader;
Good quality. Quick service. I recommend to everyone.
 ES5030R SHERWOOD Service Manual by Dinka Hristova;
Very good quality scan of the document. I am very pleased with what I got.
 SQ10 PHILIPS Service Manual by Hammad Khan;
PDF Contains Technical Data, Mechanical data, Detailed Circuit diagram with components value, PCB layout. Actual PCBs Print. Component List, Spare parts code list and Input output detail. It cover LBB1211, LBB1212, LBB1213, LBB1216, LBB1217. It is the actual Service Manual for SQ10
 AVM710 PHILIPS Service Manual by Frank Cornelis;
very good manual with clear electrical schemes. Very helpful to find wat was wrong inside my microwave.
 7/601 GLOBETROTTER NORDMENDE Service Manual by Nicolas Meyrath;
Hi, thankyou for providing the Nordmende Globetrotter original manufacturer's repair manual. Quality is very good and sharp - the PDF file was comfortably small to download. The only question is: why did it take so long to become ready for download?? Many thanks anyway, I fixed the fault in the radio thanks to the circuit. regards: Nick

Text excerpt from page 30 (click to view)
7615 Adjustments page 16

Touch-up Convergence adjustments
Enter the Digital Convergence Mode (DCM) by entering 0-6-2-5-9-7-(Status or Index) on the Remote control. The following menu will appear: Select an active channel or Aux Input. A signal must be applied to the set when performing convergence. If any Customer Adjustments need to be made, the Menu button can be used to toggle between the Customer Menu and DCM. The MPOSD ADJUST is used to center the Customer Convergence grid. A highlighted cross will appear along with the Convergence alignment grid. The highlighted cross should be centered onto the center of the Convergence grid. To perform a Touch Up Convergence, highlight SELECTION and press the right cursor button on the remote. The following menu will appear: Selections STORE, RESTORE FACTORY, and RESTORE DEFAULT are not shown after selecting SELECTION. Press the cursor down button on the Remote for these selections to appear. RESTORE FACTORY loads Convergence defaults from the Factory Loaded section of the Convergence Memory IC. RESTORE DEFAULT loads Convergence defaults from the sets software.

To perform a Touch-up Convergence:
1. Enter the Convergence Mode and select RED TO GREEN or BLUE TO GREEN. Do not select GREEN (Green Geometry) without placing a Template over the screen. To perform Green Geometry, refer to the Complete in-depth Convergence. Use the Cursor buttons on the Remote to Navigate from one adjustment point to another. Press the Status or Index button on the Remote to select ADJUST. Use the cursor buttons on the Remote to adjust the Red to Green or Blue to Green. Press the Status or Index button again to navigate to the next adjustment location. After Convergence alignments are complete, press the Menu button on the Remote to return to the SELECTION menu. Highlight the STORE selection and press the right cursor key on the Remote to save changes. Use the GREEN TO RED or GREEN TO BLUE selections to perform convergence when the Green CRT has been replaced.

2.

3. 4. 5.

Complete in-depth Convergence SCREEN CENTERING
1. 2. Make sure a signal is applied to the set. Enter the Convergence mode by entering 0-6-2-5-9-7-(Status or Index). Select an active channel or input. If the Customer settings need to be adjusted, pressing the Menu button will access the Customer menu. 3. Place a Template over the screen. 4. Select GREEN in the SELECTION menu. 5. Place a jumper across connector 1005 on the SSM to defeat convergence drive. 6. Using the centering rings on the Green CRT, center the convergence pattern onto the center point of the Convergence Template. 7. Press the Menu button on the Remote to return to the SELECTION menu. 8. Select RED TO GREEN in the menu. 9. Center the Red pattern onto the Green pattern. 10. Select BLUE TO GREEN in the SELECTION menu. 11. Center the Blue pattern onto the Green pattern. 12. Remove the Jumper on connector 1005. Note: If a CRT has been replaced, it is only necessary to perform Screen Centering for the CRT being replaced.

You might also want to buy

$4.99

55P8241 PHILIPS
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…
>
Parse Time: 0.274 - Number of Queries: 202 - Query Time: 0.077