It has all the information you will need to fix it. The main circuit diagram is only A4 but being a PDF, you can print it to any size - I did it on two sheets of A3 and it didnt lose any detail - just made it readable when pinned up above the bench. I've found the fault, just need to buy some obscure bits to get it going again!
I cant fault the process, I paid for the manual in the morning and it was ready to download by lunch time.
 ;
Very good copy in a 54 pages PDF archive. This is my sixth purchase here. :)
 ;
Another excellent buy! File too clear and explanatory.
 ;
A manual hard to find. It was very helpful to restore my device.
SCHEMATIC DIAGRAM
MODEL : 40WH08B / 40WH08G
WARNING: BEFORE SERVICING THIS CHASSIS, READ THE "X-RAY RADIATION PRECAUTION", "SAFETY PRECAUTION" AND "PRODUCT SAFETY NOTICE" ON THE MANUAL FOR THIS MODEL. CAUTION: The international hazard symbols "*" in the schematic diagram and the parts list designate components which have special characteristics important for safety and should be replaced only with types identical to those in the original circuit or specified in the parts list. The mounting position of replacements is to be identical with originals. Before replacing any of these components, read carefully the PRODUCT SAFETY NOTICE on the MANUAL for this model. Do not degrade the safety of the receiver through improper servicing.
NOTE: 1. RESISTOR
2. CAPACITOR
Resistance is shown in ohm [K = 1.000, M = 1.000.000]. All resistors are 1/6W and 5% tolerance carbon resistor, unless otherwise noted as the following marks. 1/2R = Metal or Metal oxide of 1/2 watt 1/2S = Carbon compsistion of 1/2 watt 1RF = Fuse resistor of 1 watt 10W = Cement of 10 watt K = ±10% G = ±2% F = ±1% Unless otherwise noted in schematic, all capacitor values less than 1 are expressed in
4. Voltages read with DIGITAL MULTI-METER from point indicated to chassing ground, using a color bar signal with all controls at normal, line voltage 220 volts. 5. Waveforms are taken receiving color bar signal with enough sensitivity. 6. Voltage reading shown are nominal values and may vary ±20% except H.V.
?F, and the values more than 1 in pF. All capacitors are ceramic 50V, unless otherwise noted as the following marks. Electolytic capacitor Mylar capacitor 3. The parts indicated with " * " have special characteristics, and should be replaced with identical parts only.
|
|
 |
> |
|