Good scan of the original service manual. All schematics and adjustment procedures are there. It helped me to fix a long lasting problem with the tracking circuitry. The manual also includes the supplementals 1,2 and 3. Included are; electrical schematic's , pcb layout's, mechanical drawing's and exploded views, disassembly manual and maintenance procedures. 236 pages.
 ;
The Service Manual received was helpful. The electronic information is exactly what I needed.
I recomend all of my friends about this technical page.
 ;
High quality scan of service manual. I am satisfied!
 ;
Excellent copies.
I will use "Owner Manual" again a second time.
9. At this time, Re-check that Horizontal line is white. If not, Re-adjust Cut-off Adjustment until the Horizontal Line becomes pure white. 10. Turn off and on again to return to normal mode. Receive APL 100% white signal and Check Chroma temperatures become 9200K (x: 286 / y: 294)±3%. Note: Confirm that Cut Off Adj. is correct after this adjustment, and attempt Cut Off Adj. if needed.
4. Press [VOL o / p] button on the service remote control unit and select �U-Offset YUV (Magenta)� mode. 5. Press [CH o / p] buttons so that the waveform of the �U-Offset YUV (Magenta)� mode is equal to the waveform of the �U-Offset YUV (Cyan)� mode.
16. V-Offset YUV
1. In VIDEO mode (white 50%) of YUV, press [3] button on the service remote control unit and select �V-Offset YUV� mode. (Display change �UOffset�, �V-Offset�, �U-Offset YUV� and �V-Offset YUV� cyclically when [3] button pressed.) 2. Press [VOL o / p] button on the service remote control unit and select �V-Offset YUV (Cyan)� mode. 3. Check the waveform of the base of Q1511 on the CRT CBA with the oscilloscope. 4. Press [VOL o / p] button on the service remote control unit and select �V-Offset YUV (Magenta)� mode. 5. Press [CH o / p] buttons so that the waveform of the �V-Offset YUV (Magenta)� mode is equal to the waveform of the �V-Offset YUV (Cyan)� mode.
13. U-Offset
1. In VIDEO mode (white 50%) of V1 or V2, press [3] button on the service remote control unit and select �U-Offset� mode. (Display change �UOffset�, �V-Offset�, �U-Offset YUV� and �V-Offset YUV� cyclically when [3] button pressed.) 2. Press [VOL o / p] button on the service remote control unit and select �U-Offset (Cyan)� mode. 3. Check the waveform of the base of Q1531 on the CRT CBA with the oscilloscope. 4. Press [VOL o / p] button on the service remote control unit and select �U-Offset (Magenta)� mode. 5. Press [CH o / p] buttons so that the waveform of the �U-Offset (Magenta)� mode is equal to the waveform of the �U-Offset (Cyan)� mode.
14. V-Offset
1. In VIDEO mode (white 50%) of V1 or V2, press [3] button on the service remote control unit and select �V-Offset� mode. (Display change �UOffset�, �V-Offset�, �U-Offset YUV� and �V-Offset YUV� cyclically when [3] button pressed.) 2. Press [VOL o / p] button on the service remote control unit and select �V-Offset (Cyan)� mode. 3. Check the waveform of the base of Q1511 on the CRT CBA with the oscilloscope. 4. Press [VOL o / p] button on the service remote control unit and select �V-Offset (Magenta)� mode. 5. Press [CH o / p] buttons so that the waveform of the �V-Offset (Magenta)� mode is equal to the waveform of the �V-Offset (Cyan)� mode.
15. U-Offset YUV
1. In VIDEO mode (white 50%) of YUV, press [3] button on the service remote control unit and select �U-Offset YUV� mode. (Display change �UOffset�, �V-Offset�, �U-Offset YUV� and �V-Offset YUV� cyclically when [3] button pressed.) 2. Press [VOL o / p] button on the service remote control unit and select �U-Offset YUV (Cyan)� mode. 3. Check the waveform of the base of Q1531 on the CRT CBA with the oscilloscope.