The schematic is very helpful and the images are very good.The schematic is very helpful and the images are very good.The schematic is very helpful and the images are very good.The schematic is very helpful and the images are very good.The schematic is very helpful and the images are very good.The schematic is very helpful and the images are very good.
 ;
Welcome. The scheme is clearly helped me to repair. Worth to download it.
66GF-64H
barrel shape. � When the volume down button is pressed, side pincushion changes from pincushion to barrel shape. � Press the stand-by button on the remote control to store.
Corner Symmetry Adjust the Corner Symmetry so that the picture is centred. The effect of this adjustment is shown in figure 7. Note: This adjustment affects to upper and lower sides. � When the volume up button is pressed, side pincushion changes from pincushion to barrel shape. � When the volume down button is pressed, side pincushion changes from pincushion to barrel shape. � Press the stand-by button on the remote control to store.
Fig.7
Vertical Linearity Adjust the Vertical Linearity so that the upper and lower parts of the picture are symmetrical. The effect of this adjustment is shown in figure 8. � When the volume up button is pressed, the upper picture scanning decreases and the lower picture scanning increases. � When the volume down button is pressed, the upper picture scanning increases and the lower picture scanning decreases. � Press the stand-by button on the remote control to store.
Fig.8
Vertical Amplitude Adjust the Vertical Amplitude so that the picture is over-scanned. The effect of this adjustment is shown in figure 9. � When the volume up button is pressed, the vertical size of the picture increases. � When the volume down button is pressed, the vertical size of the picture decreases. � Press the stand-by button on the remote control to store.
Fig.9
S Correction Adjust the S Correction so that the picture symmetrical between the top, centre and bottom. The effect of this adjustment is shown in figure 10. � When the volume up button is pressed, the top and bottom scanning increases and the centre scanning decreases. � When the volume down button is pressed the top and bottom scanning decreases and the centre scanning increases. � Press the stand-by button on the remote control to store.
Fig.10
Vertical Shift Adjust the Vertical Shift so that the picture is centred. The effect of this adjustment is shown in figure 11. � When the volume up button is pressed, the picture moves up. � When the volume down button is pressed, the picture moves down. � Press the stand-by button on the remote control to store.