This Service manual is very well scanned and its clean to read, no any anti-theft words that un-english could understand. I got my CCD600 working with this manual and it´s clear shematics :)
 ;
I was very pleased with the service provided and was surprised at how good the quality was of the manual. I thought it may be a third generation copy or so, but it is as good as the websites that charge 3 times this much. I repair some electronics for family and friends without charge, so this is perfect for me. Thank you very much.
 ;
The service was great and the document was also great. Highly recommend!!!!
If anyone has a users manual... Please email me. need one. $ filippo611@aol.com
 ;
I needed a service manual as the display on my oscilloscope was very dim. I thought I'd give owner-manuals.com a try, as they advertised a huge number of manuals. Sure enough they had one listed. I bought it hoping it would be useful... actually, I bought it hoping it would be readable! I've had manuals from online sources in the past, and been very disappointed. Not this time! An excellent manual, complete, and very readable. Using it I fixed my 'scope, and as such the manual was an investment that paid off manyfold. Do I have any complaints? One very minor one - The circuit diagrams could have been scanned at a higher resolution, as some of the details were a little difficult to make out - not impossible, just not as easy as my old eyes would like! Overall, I'm very satisfied with my manual, and I will certainly be using this company again. Well done.
 ;
I Have looked for this manual for quiet a while now, I have finally found it here. I believe this is the only place they have them in a very nice scan, pages are very clear to read, some of the pages are a bit tilted but overall it is great to have this manual available for purchase. Thanks
4. Checking the Drainage and Forming the Pipings
1) Checking the drainage
1. To remove the front panel from the indoor unit, remove the front panel from the indoor unit cabinet. Set the air direction louvers up-and-down to the position(horizontally) by hand. Remove the securing screws that retain the front panel. Pull the lower left and right sides of the grille toward you and lift it off.
2) Form the piping
1. Form the piping by wrapping the connecting portion of the indoor unit with insulation material and secure it with two kinds of vinyl tapes. If you want to connect an additional drain hose, the end of the drain outlet should be routed above the ground. Secure the drain hose appropriately. 2. In cases where the outdoor unit is installed below the indoor unit perform the following. Tape the piping, drain hose and connecting cable from down to up.
Screw
Seal small openings around pipings with a gum type sealer.
Pull the right and the left side.
2. To check the drainage. Pour a glass of water on the evaporator. Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit.
Secure the tapped piping along the exterior wall using saddle or equivalent.
Taping Drain hose
, ,
Trap is required to prevent water from entering into electrical parts.
Seal a small opening around the pipings with gum type sealer. Trap
Pipings Connecting cable
3. In cases where the Outdoor unit is installed above the Indoor unit perform the following. Tape the piping and connecting cable from down to up. Secure the taped piping along the exterior wall. Form a trap to prevent water entering the room. Fix the piping onto the wall by saddle or equivalent.
3. Drain piping The drain hose should point downward for easy drain flow.
Downward slope
Do not make drain piping.
Do not raise Accumulated drain water Air
, ,
Tip of drain hose dipped in water Less than 50mm gap Ditch
Trap
Water leakage Water leakage Waving Water leakage
- 34 -
|
|
 |
> |
|