Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I do not have very much to say.
The price is quite covenient, delivery was better as promised (about 12 ours, against the specified 24 hours if I remember well), and the quality of the PDF is more than acceptable.
The Service Manual of Sansui R30 itself is also satisfactory: good graphic for schematics and layouts, simple and well structured.
Giovanni Bianchi
 ;
Happy to find finally a schematic for this amplifier. The schematic is of good quality, the pcb layout is useless: all is black. Never the less, it is very easy to find the components on the board using the schematics.
 ;
Hard to find manual was ready the next day. Scans were very legible (including schematics). All the essential parts of the service manual were present (adjustment procedure, schematics, and parts list). It would have been nice if the rest of the manual was included (disassembly procedure, theory of operation, etc.).
 ;
The Service Manual for the Kenwood KR-V55R provided by owner-manuals.com was as described/advertised. The contents provided the necessary information to effect a diagnosis of the unit. The schematics above all else was instrumental in tracing the the signal flow from component to component.
 ;
This manual was the factory original. Excellent value and contained all the details I needed. Easy dowwnload provided the information when I needed it.
D
Vorbereitende Arbeiten
GB
Preparatory steps
Bevor Sie den elektrischen Abgleich durchführen, müssen Sie folgende Vorbereitungen treffen: Höhen - Einstellung ........................................................................ 0 Bass - Einstellung .......................................................................... 0 Fader - Einstellung (nicht Lübeck/Luxembourg) ............................ 0 Balance - Einstellung ..................................................................... 0 Loudness - Einstellung (DSC Menü) .............................. 1 oder OFF
Observe the following preparations before performing the electrical alignment: Treble adjustment .......................................................................... 0 Bass adjustment ............................................................................ 0 Fader adjustment (not Lübeck/Luxembourg) ................................. 0 Balance adjustment ....................................................................... 0 Loudness adjustment (DSC menu) .................................... 1 or OFF
Lautsprecheranschlu�
Der Lautsprecherausgang mu� mit 4 � abgeschlossen sein.
Loudspeaker connections
The loudspeaker output must be terminated with 4 �.
Abgleichhinweise
Wellenbereich: FM = 87,5 MHz - 108,0 MHz (100 kHz automatische Suchlaufschritte) (50 kHz manuelle Suchlaufschritte) MW = 531 kHz - 1602 kHz (9 kHz automatische Suchlaufschritte) (9 kHz manuelle Suchlaufschritte) LW = 153 kHz - 279 kHz (9 kHz automatische Suchlaufschritte) (1 kHz manuelle Suchlaufschritte)
Notes on alignment
Waveband: FM = 87.5 MHz - 108.0 MHz (100 kHz automatic search steps) (50 kHz manual search steps)
MW = 531 kHz - 1602 kHz (9 kHz automatic search steps) (9 kHz manual search steps) LW = 153 kHz - 279 kHz (9 kHz automatic search steps) (1 kHz manual search steps)
Für den Abgleich müssen Sie die Stationstasten mit folgenden Frequenzen programmieren: Taste FM1 MHz MW kHz LW kHz 1 98,1 531 162 2 98,1 558 198 3 98,1 558 198 4 98,1 1521 5 98,1 1602 6 91,1
The station preset push-buttons have to be be programmed for the alignment to the following frequencies : Push-button 1 FM1 MHz MW kHz LW kHz 98.1 531 162 2 98.1 558 198 3 98.1 558 198 4 98.1 1521 5 98.1 1602 6 91.1
AM + FM - Abgleich:
Den AM- und FM-Abgleich müssen Sie durchführen, wenn bei einer Reparatur frequenzbestimmende Bauteile ausgetauscht oder verstellt wurden. Nach Reparatur-/ Abgleicharbeiten müssen die Geräteparameter neu programmiert werden.
AM + FM alignment:
The AM and FM alignment has to be carried out if components that determine the circuit's frequency have been replaced or detuned. After a repair or alignment job the basic parameters of the product have to be reprogrammed.
-
-
Abschirmung
Der HF-Abgleich mu� mit Unterdeckel erfolgen. Hierzu ist es ratsam da� Sie an die Me�punkte Leitungen anzulöten. Führen Sie die Leitungen nach oben oder seitlich aus dem Gerät heraus.
Radio-shielding
The r-f alignment has to be performed with the bottom cover in place. It is advisable to solder wires to the measuring points and provide access from the top of the the main board or out through holes in the side of the frame.