Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
It's a full manual. All the parts are in there. I haven't found the problem yett, but I am working on it; hope I can rebuild the part myself. To make it more secure and unbreakable this time. Because the part has failed several times before and costs a lot to let it be repaired.
Thanks so much for this rich illustrated and parted manual.
 ;
I downloaded the document. The manual was complete, well scanned and everything was legible. I could zoom in see what I needed to know. There's not much more that you can ask.
 ;
It was complete service manual with all needed service informations. Thanks.
 ;
El manual esta muy detallado, los numeros de partes y los esquemas de despiece son correctísimos y muy claros, tanto para los técnicos experimentados como para los novatos.
 ;
Ottima qualità grafica e completo nelle notizie. Costo abbastanza contenuto.
Dolby®-Pegeleinstellung
Me�punkte ............................... MP 1377, MP 1378 Signalquelle ............................. Dolby®-Testcassette 400 Hz / 200 nWb/m Abgleichelemente .................... R 1241, R 1261 Spezifikation ............................ 450 mV ± 27 mV 1. Schalten Sie die Dolby®-Funktion aus. 2. Legen Sie die Dolby®-Testcassette in den Cassettenschacht ein, und starten Sie die Wiedergabe. 3. Stellen Sie mit R 1241 einen Pegel von 450 mV ± 27 mV an MP 1277 ein. Stellen Sie mit R 1261 einen Pegel von 450 mV ± 27 mV an MP 1278 ein.
* Rauschunterdrückungssystem unter Lizenz von Dolby Laboratories hergestellt. Das Wort Dolby und das Symbol des doppelten D sind die Markenzeichen von Dolby Laboratories.
Dolby® Adjustment
Measuring points ..................... MP 1377, MP 1378 Signal source ........................... Dolby® test cassette 400 Hz / 200 nWb/m Alignment elements ................. R 1241, R 1261 Specification ............................ 450 mV ± 27 mV 1. Switch Dolby® off. 2. Insert the Dolby® test cassette into the cassette compartment. Start tape play. 3. Use R 1241 to adjust a level of 450 mV ± 27 mV at MP 1277. Use R 1261 to adjust a level of 450 mV ± 27 mV at MP 1278.
* Noise reduction system manufatured under the licence of Dolby Laboratories. The Dolby logo and the double D Dolby symbol are registered trademarks of Dolby Laboratories.
Logik-Platte Logic board
PL 0312 A05
R1261
R1241
6 8 1
1377
4 1
8
1
D1140
9 16
D1250
9 11 16
D1350
5 8
1378
R1261 R1241
- 11 -
|
|
 |
> |
|