Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Sweet! I won the item on eBay and couldn't adjust the geometry or even keep a steady picure. This guide has the full schematics (not available anywhere else as far as I could tell), and was a bargain for the wealth of knowledge it contains. I hooked it up to my testing equipment, tweaked a few potentiometers and got it playing videogames in no time. Thanks!
 ;
It was just what I need to fix my old BMW's CD player. Very convenient also. Thank you.
 ;
Great Manual! It contains all the wiring schematics and mechanical exploded views that are essential for service and repair. I was surprised I even found this for such an old machine. Only wish I knew of this site many years ago.
 ;
Great manual very clear copied. You are making an incredible job. I appreciate a lot the rapidity and your efficiency. Thanks a lot
 ;
Good pdf of the service manual for this unit. Includes disassembly instructions, full schematics, board layouts, parts lists and diagnostic information. Some information is in the pdf twice (single pages, and split pages), but that could be how it was originally generated by panasonic, or perhaps the idea is to make it eaiser to put onto 8.5 x 11" pages.
Information was exactly what I needed. Delivery was overnight (less than 12 hours) and I was happy with the process.
Dolby®-Pegeleinstellung
Me�punkte ............................... MP 1377, MP 1378 Signalquelle ............................. Dolby®-Testcassette 400 Hz / 200 nWb/m Abgleichelemente .................... R 1241, R 1261 Spezifikation ............................ 450 mV ± 27 mV 1. Schalten Sie die Dolby®-Funktion aus. 2. Legen Sie die Dolby®-Testcassette in den Cassettenschacht ein, und starten Sie die Wiedergabe. 3. Stellen Sie mit R 1241 einen Pegel von 450 mV ± 27 mV an MP 1277 ein. Stellen Sie mit R 1261 einen Pegel von 450 mV ± 27 mV an MP 1278 ein.
* Rauschunterdrückungssystem unter Lizenz von Dolby Laboratories hergestellt. Das Wort Dolby und das Symbol des doppelten D sind die Markenzeichen von Dolby Laboratories.
Dolby® Adjustment
Measuring points ..................... MP 1377, MP 1378 Signal source ........................... Dolby® test cassette 400 Hz / 200 nWb/m Alignment elements ................. R 1241, R 1261 Specification ............................ 450 mV ± 27 mV 1. Switch Dolby® off. 2. Insert the Dolby® test cassette into the cassette compartment. Start tape play. 3. Use R 1241 to adjust a level of 450 mV ± 27 mV at MP 1277. Use R 1261 to adjust a level of 450 mV ± 27 mV at MP 1278.
* Noise reduction system manufatured under the licence of Dolby Laboratories. The Dolby logo and the double D Dolby symbol are registered trademarks of Dolby Laboratories.
Logik-Platte Logic board
PL 0312 A05
R1261
R1241
6 8 1
1377
4 1
8
1
D1140
9 16
D1250
9 11 16
D1350
5 8
1378
R1261 R1241