This service manual includes drawings, schematics, exploded views, parts list, operating details, and more. Very good scans, very readable. The only thing that made it a 4 star rating was on approximately 4 scans only half of the page was scanned then the other half. I would have preferred the pages to be whole scans.
 ;
Good manual contains all it takes to update, repair,these types of mixers.Thanks.
 ;
Great service. Fast response. High quality scan. Good price.
Thank you very much!!!
Oleg S.
 ;
Well-scanned, complete manual. Contains the information needed for repair and maintenance.
 ;
It's great to be able to obtain a precious technical information for a real old equipment. The one I got helps me a lot in the area of wiring diagram to repair my antique. PDF gave me clear enough information to find out thr details. Thanks for giving me the oppotunity to be able to access to almost vanished informations.
CTV990107
Month of Issue: Classification:
CTV991202 TELEVISION TECHNICAL BULLETIN
Month of Issue: December 1999 Classification: White Page 1 of 1
TELEVISION TECHNICAL BULLETIN
PHILIPS CRT Original deflection yoke PWB shown on left
January 1999 White Page 3 of 3
MODELS
66DW18H
76DW18H
76EF19H
76EF20H
CONNE
Orange Yellow Green
Connector 1
SYMPTOM The following problems can occur on the 100Hz PWB.
Red Yellow Red Orange Green
� � �
�
Intermittent digital noise on the picture Intermittent mosaic squares on the picture Mosaic effect if the 100Hz PWB is tapped Red, green or blue screen if the 100Hz PWB is tapped
KC lead
CAUSE
Problems around the field mixer IC, SDA9270. � � IC6108 in the 66DW18H and 76DW18H IC6105 in the 76EF19H and 76EF20H
ACTION
Carry out the following counter measures. 1. Make sure that there are no dry joints on the Mother PWB 2. Resolder IC6108/IC6105 by reflowing the device - it is not necessary to remove IC6108/IC6105 Note that you can operate the 100Hz PWB with the shield cans removed. It is important that these are returned to there original condition when the job is completed.
To change the deflection yoke wiring from a Thomson CRT to a Philips CRT, proceed as follows 1. 2. 3. Unsolder both the green and yellow (FV) and red and orange (FH) leads from the deflection yoke PWB. Solder these leads to the Philips CRT as shown above. Replace wire KC (QCNW-2775BMZZ) that connects from the CRT socket PWB to the neck of the CRT with lead QCNW-2757BMZZ.
Sharp Electronics (UK) Limited
Sharp Electronics (UK) Limited Originator AvW Supervisor Approval Date / / Reference SP84001X Revision 2 White � Carry out as required, Yellow � Carry out as required and whenever the unit comes in for service, Red � Carry out on all units
Reference JR031299-1 Revision 2 White � Carry out as required, Yellow � Carry out as required and whenever the unit comes in for service, Red � Carry out on all units
|
|
 |
> |
|