I was very pleased with the manual I got for my amateur (ham) radio. Without it I could not figure out how to input and/or change the P/L setting on my radio. It drove me nuts as the radio was essentially useless. That all changed when my manual came. Then it took only minutes and I was done. Now my radio works fine. This is an exceptionally good resource as it's a very easy and user friendly download. Thank you very much! Dziękujemy za!
 ;
It answered my question, which was how to load the paper. I did notice that the very end of the manual was not visible.
 ;
The product manual I received was exactly what I was looking for, delivered painlessly at a very fair price. I can't ask for any more than that.
Cleaning the Dehumidifier
NOTE: Be sure float is snapped in place.
Exterior
NOTE: Have an authorized service technician clean and service the interior coils of your product annually. 1. Turn off dehumidifier. 2. Dust front grille and side panels with a soft brush or the dusting attachment of your vacuum cleaner.
A
Water Bucket
Every few weeks, rinse the inside of the water bucket with a mild detergent to avoid growth of mold, mildew and bacteria.
B
Water Level Float
The dehumidifier has an Empty/Adjust Bucket light and a water level float. The bucket must be properly aligned for the water level float and Empty/Adjust Bucket light to work.
A. Water level float B. Bucket
TROUBLESHOOTING
Before calling for service, try the suggestions below to see whether you can solve your problem without outside help. Dehumidifier will not run
s
Ice forms on coils
s
Is the dehumidifier turned on? Turn on dehumidifier.
WARNING
s
Model AD25B dehumidifiers do not have an automatic deicer. See model and serial number label for model number. If ice forms on coils, unplug dehumidifier until ice melts and room temperature rises. All models, except AD25B, have an automatic deicer that will shut off the compressor and allow the fan to run. This reduces the ice buildup on the coils. The compressor will cycle back on when the deicer senses the correct operating temperature.
Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock.
s s s s
Dehumidifier runs but does not dehumidify
Do you have model AD25D? Units with this model number have a deicer that will shut off the compressor and allow the fan to run. When the deicer senses the correct operating temperature, the compressor will cycle back on. Do you have control type 2 or 3? Units with these control types have a deicer that will shut off the compressor and allow the fan to run. When the deicer senses the correct operating temperature, the compressor will cycle back on. Do you have control type 3? If you have selected Continuous Run, the dehumidifier will run continuously. If the humidity level is low, little or no water may be collected. The filter (on some models) is dirty or obstructed by debris. Clean the filter.
Is the power cord plugged into a grounded 3 prong outlet? Plug into a grounded 3 prong outlet. See �Electrical Requirements.� Has a household fuse blown, or has a circuit breaker tripped? Replace the fuse or reset the circuit breaker. If the problem continues, call an electrician. See �Electrical Requirements.� Is bucket installed properly? Reinstall bucket so that it fits all the way into the dehumidifier. Does bucket need to be emptied? Empty bucket. Is water level float in place? Remove bucket. Make sure float is snapped in place. Reinstall bucket.
s
s
Air coming from dehumidifier is warm
s
s
Dehumidifier will put out warm air under normal operating conditions.
s s
8
|
|
 |
> |
|