Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
The owners manual is very good. all my how to questions were answered in detail.
 ;
Irrespectively of this manual exist only germany language, it's useful - although i need some additional task to translate: My english is bad, but usable - but i really dont speak germany. :)
 ;
Excellent service from this company (including a total refund on an earlier purchase when through no fault of the company the manual was incomplete). I have purchased several manuals which I have been very satisfied with, as I am with this one. Highly recommended.
 ;
It was easy to order and received exactly what I needed. Only complaint would be the 24 hours you have to wait.
 ;
Manual was delivered in a timely manner and was all in English as advertised. The manuals I received when we moved into our flat were in German, Italian, and French. Having never used a steamer before, and not speaking/reading German very well, I needed an English Manual. this was a huge help.
Supplementary Notes
How to connect the VM-3100Pro and the ADA-7000
Connection
Connect the VM-3100Pro and the ADA-7000 with the R-BUS cable attached in the ADA-7000 box.
Booting up
Turn the power on the ADA-7000 first, then VM-3100Pro.
Sampling clock setting
If clock source has not been set, noise may be generated from the audio output on the ADA-7000 and the VM3100Pro. While setting the clock source, please turn down the master and monitor level, and turn up again after the setting is finished. Set the sampling clock of the ADA-7000 and the VM-3100Pro as follows.
Clock Source on the ADA-7000: Master clock on the VM-3100Pro: R-BUS INTERNAL
ADA-7000 setting
Check if the clock source on the ADA-7000 is set to R-BUS. When the ADA-7000 is booted up, the clock source is set to R-BUS. * Refer to ADA-7000 Owner�s Manual p. 6 �Clock source.�
VM-3100Pro setting
Set the master clock of the VM-3100Pro to INTERNAL as follows.
1. 2. Hold down [SHIFT], and press [DIGITAL IN]. Press [F1 (�INT)].
* Sample rate of the VM-3100Pro is fixed to 44.1kHz. If you use the VM-3100Pro and the ADA-7000 in combination, the ADA-7000 works in 44.1kHz sample rate. * If you set the clock source differently, please refer to the ADA-7000 Owner�s Manual p. 6 �Clock source� and the VM-3100Pro Owner�s Manual p. 52 �Inputting signals from digital devices.�
How to connect the VSR-880 and the ADA-7000
Connection
Connect the VSR-880 and the ADA-7000 with the R-BUS cable attached in the ADA-7000 box.
Booting up
Turn the power on the ADA-7000 first, then VSR-880.
Sampling clock setting
Set the sampling clock of the ADA-7000 and the VSR-880 as follows. If clock source has not been set, noise may be generated from the audio output on the ADA-7000 and the VSR-880. While setting the clock source, please turn down the master and monitor level, and turn up again after the setting is finished.
Clock Source on the ADA-7000: Master clock on the VSR-880: R-BUS INTERNAL
18
|
|
 |
> |
|