1. The C-4 chart�s vertical lines do not overlap properly. On the right side of the chart, the yellow line is to the left of the black line and the cyan line is to the right of the black line. The yellow line�s edge is the most distant edge from the black line. These conditions are used to determine what the new values should be. The new value is located in the bottom row, to the left of the current value�s column. For the right side of the chart, the machine�s current red correction value is 6 (4-932-2), and the blue correction value is 5 (4-932-4). Therefore, the current value in the chart is 65. The new value (bottom row to the left) is 56. 2. On the left side of the chart, the cyan line is to the left of the black line and the yellow line is to the right of the black line. The edges of the yellow and cyan lines deviate evenly from the black line. These conditions are used to determine what the new values should be. The new value is located in the middle row, to the right of the current value�s column. For the left side of the chart, the machine�s current red correction value is 6 (4-932-1), and the blue correction value is 4 (4-932-3). Therefore, the current value in the chart is 64. The new value (middle row to the right) is 73.
6-29
Replacement Adjustment
|