complete wiring diagram, without the part list. high quality copy. thanks for promptly.
 ;
Well done scan of a useful manual. It will be useful in my workbench!!
 ;
Excelent scan job. It's a fully detailed service manual of this model.
 ;
Do a quick order, scan quality is high.
I recommend to all!
 ;
This manual is perfect! Just what I needed. Thanks!
8-5. White balance Adjustment
1. Connect the oscilloscope to �MON_CB� and �MON_G� on the VFK1308P. 2. Open the �LCD adjustment menu�. 3. Select �5. White balance adjustment� in the LCD adjustment menu, and then press the �Enter� key.
4. Adjust level difference between �a� (MON_CB) and �b� (MON_G) to become +50mV±50mV as shown in figure. Note: 1) Signal level can be adjusted by press arrow keys on keyboard. 2) Waveform (figure) can be displayed by press F2 key. 5. When adjustment is finished, press ENTER key to adjusted data write to EEPROM, then change the display indicated as below.
6. Connect the oscilloscope to �MON_B� and �MON_G� on the VFK1308P. 7. Adjust level difference between �a� (MON_B) and �b� (MON_G) to become +300mV±50mV as shown in figure. Note: 1) Signal level can be adjusted by press arrow keys on keyboard. 2) Waveform (figure) can be displayed by press F2 key. 8. When adjustment is finished, press ENTER key to adjusted data write to EEPROM.