Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
As the only source for this manual it rather rank quite high since it is well scanned and perfectly readable.
 ;
the manual is in good quality and it's in pdf. manual was send in less then 24h.
regards
mike
 ;
I would not plug this machine in without finding a manual like this. In addition to setup and normal operating instructions, it has troubleshooting flowcharts, diagrammed mechanical adjustments, and schematics to beat the band. The tech I hand it to would be thrilled to find solder side PCB diagrams with component outlines superimposed, pinouts for every IC chip, and line drawings of transistors, with labeled legs.
As for printing quality, this may be a copy of a copy, but even the finest print when enlarged is very legible. There is a bit of grayed print over a few pages, as if a wet page were placed over it, but the print is still very legible. If you could borrow an original manual and get it printed and bound for 4 to 6 times the cost, you could get better quality. In that case you wouldn't be here. For price, utility, and availability I am rating this manual highly.
 ;
I received the Manual in a timely manner and it was exactly what I needed.
This is a perfect copy of the Service Manual, The quality is great. I am very
happy. Thank you
 ;
exactly as they say. Within 24 hours the link to the pages and offcourse it was the right service manual. Super and thanks
Output Level Measurement Point R-CH Input Level Measurement Point L-CH 47 kohm 47 kohm
Input Point Scope
VTVM
Adjust with Frequency Counter Connected Test Tape : MTT-111N(3kHz) MTT-5511(Blank) Set Output Level Measurement Point Forward Side Reverse Side Frequency Counter
L-CH Peak within 1 dB R-CH Peak Output Level within 1 dB
Test Tape MTT-114N (10kHz)
L-CH
Oscilloscope
Set
V
H
Screw Angle
Output Level Measurement Point Screen Pattern
L-CH Peak
R-CH Peak
Screw Angle
In Phase 45 Good
90
135
180
Wrong
|
|
 |
> |
|