Description of SHARP AR-153E Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 SU6/K TECHNICS Service Manual by Rajesh Tanna;
Very clear copy. No pages missing. Big bonus is that it includes supplement. Price is affordable compared to what others ask for.
 TM-1010PN JVC Service Manual by Ken Stevens;
Found the quality of the copy excellent and a very quick service. I would certainly recommend the service.
 RK100/L JVC Service Manual by Menahem Yachad;
Good quality, clear diagrams. Exactly what I needed.
 KRFX7775D KENWOOD Service Manual by H. Zeilstra;
Good product. All the information is invcluded, but due to the complexity of the amplifier, it still is difficult to get it to operation again.
 STR-6055 SONY Service Manual by Teresa RIGAULT;
Very professional seller; very fast, accurate and rielable service.

Text excerpt from page 92 (click to view)
3. Density level adjustment
A. AE level adjustment (OC mode)
[Input procedure]
When the density select key is pressed and held for 5 sec after turning on the [PHOTO] mode lamp, the [AUTO] mode lamp blinks and the current setup of the density level is displayed.

4. Toner save mode setup and cancel
[Input procedure]
When the density select key is pressed and held for 5 sec after turning on the [TEXT] mode lamp, the [PHOTO] mode lamp blinks and the current setup of the density level is displayed.

[Setup/Cancel]
When the density adjustment key [<] is pressed, Level 1 is lighted and the toner save mode is set. When the density adjustment key [>] is pressed, Level 5 is lighted and the toner save mode is canceled.

[Adjustment]
The adjustment is made in 5 steps by pressing the density adjustment key.

[Terminating procedure]
When the density select key is pressed, the mode display is changed from blinking to lighting, and the AE level setup is completed. � In the AE level adjustment mode, all the keys except for the [Density select] key, the [Density adjustment] keys ([>] key and [<] key) are disabled. � In the AE level adjustment mode, the ready lamp and the online lamp are turned off. � The auto mode level adjustment is applied only for the auto mode. � When the machine enters the exposure adjustment mode of OC once, the adjustment mode is not changed though a document is set on the SPF until the setup is completed.

[Terminating procedure]
When the density select key is pressed, the mode display is changed from blinking to lighting, and the setup is completed. � During the toner save mode setup, all the keys except for the [Density select] key, the [Density adjustment] keys ([>] key and [ <] key) are disabled. � During the toner save mode setup, the ready lamp and the online lamp are turned off. � The toner save mode is applied in the auto mode and the manual mode.

B. AE level adjustment (SPF mode)
[Input procedure]
With the SPF mode lamp ON, when the density select key is pressed and held for 5 sec after turning on the [PHOTO] mode lamp, the [AUTO] mode lamp blinks and the current setup of the density level is displayed.

[Adjustment]
The adjustment is made in 5 steps by pressing the density adjustment key.

[Terminating procedure]
When the mode select key is pressed, the mode display is changed from blinking to lighting, and the AE level setup is completed. � During the AE level adjustment mode, all the keys except for the [Density select] key, the [Density adjustment] keys ([>] key and [<] key) are disabled. � During the AE level adjustment mode, the ready lamp and the online lamp are turned off. � The auto mode level adjustment is applied only for the auto mode. � When the machine enters the SPF exposure adjustment mode once, the adjustment mode is not changed though a document is removed from the SPF until the setup is completed. � This function is not available for the OC model.

AR-122E/152E/153E/157E USER PROGRAMS 12 - 2

You might also want to buy

$4.99

AR153E SHARP
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

AR-153E SHARP
Parts Catalog

Parts Catalog only. It's available in PDF format. Useful, if Your equipment is broken and You need t…
>
Parse Time: 0.236 - Number of Queries: 101 - Query Time: 0.054