AR-F151 7) Clean the cleaning section and the waste toner pipe to remove waste toner completely with a vacuum cleaner. 8) Remove the felt and duplex tape completely. Note: Be careful not to scratch or bend the sub blade. 9) Attach the cleaning blade. Securely insert the plate section of the cleaning blade into the dove and fix it with a screw. Do not touch the cleaning blade rubber with your hand. When attaching the cleaning blade, press the cleaning blade in the arrow direction and attach. 12) Attach the drum fixing plate and the photoconductor drum. Apply grease to the inside of the photoconductor drum. (Dia. 2)
10) Attach the felt.
Attach the drum from (b). (Prevention against the sub blade edge breakage) Attach the drum so that its position with the sub blade is as shown. 13) Attach the detection gear. Note: � The detection gear is not installed to the drum cartridge packed with the main body. Add a new one.
Attach the mocket with slightly pressing section A of the cleaning blade. Do not touch the tip of the cleaning blade. Do not put the mocket under the cleaning blade. Do not put the mocket on the sub blade. Do not press the sub blade with the mocket. 11) Attach the main charger. Securely set the MC holder on the projection of the process frame. Securely insert two projections of the MC holder into the groove in the process frame. When attaching the MC holder ass�y, be careful not to make contact with the cleaning blade.
14) Attach the drum cover. Note: After attaching the drum cover, do not make a copy. When attaching the drum cover, engage the detection gear 20T rib with the 30T gear rib, and attach the drum cover to the process frame. 15) Mark the number of times of recycling on the side of the cover with white paint. Max. times of recycling: 5 times
3 � 11
Note: Another method of cleaning the drum counter is available with SIM 24-07.