Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Easy to order the manual. Good quality and fast delivery.
 ;
The Service Manual for Sansui AU-9500 was very helpfull, in complete and in good printable condition.
Thanks.
 ;
Dear Sir,
Document is original service document of sharp. I had a problem with the door contacts. Fuses where blown. With the manual in a few minuts is was clear what the problem was.
Manual was of great help.
With kind regards,
Martie Verhoeven
The Netherlands.
 ;
The scan is clear and well readable with very few weaker spots, usually on black background with white letters, but with enough zoom those spots can be read.
Printout is clear, the manual is complete and has all pages scanned.
I would give 5 stars, except that it is not in color, and the schematic and PCB pages are scanned on multiple pages. The document is locked (except printing) so the pages can not be extracted to compose them together for printing on the large plotter
It is worth the price tag.
 ;
let's say first that i do not need to have a credit for my opinion, i am a retired sparkie and i voluteerd to fix an electronic device for a local "Youthgroup",as no diagram was present i checked the "net" and gambled on this site and paying some fee via PayPall, i was gladly surprised that the manual arrived as was stated, GOOD SHOW, and best wishes, John
E. Resist quantity adjustment
This adjustment is performed in the following cases: �When the void quantity is changed by the paper feed tray. �When paper feed skew occurs. Before executing this adjustment, the following adjustments must have been completed. �LSU right-angle adjustment �Print magnification ratio adjustment �Print off-center adjustment �Void area adjustment 1) Hold and push the [MENU] key and the [OK] key, turn on the power. ("PCU DIAG MODE ***" is displayed.) * Do not touch the keys for about 8sec after releasing fingers from the above keys. 2) Push the [MENU] key several times until "TEST PRINT" is displayed, and push the [OK] key to enter the test print mode. 3) Make a print with "71" from each paper feed tray. 4) Push the [MENU] key several times until PAPER BUCKLE is displayed. Adjust the resist quantity so that paper is transported normally. <Factory setup> PAPER BUCKLE 45CPM MFT T1 T2 T3 T4 MFT T1 T2 T3 T4 60 70 55 55 60 65 75 60 60 65
G. Manual feed section paper guide position adjustment
This adjustment is performed in the following cases: �When the duplex unit with the manual feed unit is installed. �When the manual feed tray paper size detection fails. 1) Hold and push the [MENU] key and the [OK] key, turn on the power. ("PCU DIAG MODE ***" is displayed.) * Do not touch the keys for about 8sec after releasing fingers from the above keys.
" ON "
2) Push the [MENU] key several times until "SIZE ADJUSTMENT A" is displayed, and push [ ] key to display "SIZE ADJUSTMENT B" and push the [OK] key. 3) "MAXIMUM SIZE" is displayed on the LCD. Check the value displayed with MAXIMUM SIZE. Use [ ] or [ ] key to make the displayed value same as the MAX value specified on the label (* Note). 4) "P1 SIZE" and a value are displayed. Use [ ] or [ ] key to make the displayed value same as the P1 value specified on the label (* Note). 5) "P2 SIZE" and a value are displayed. Use [ ] or [ ] key to make the displayed value same as the P2 value specified on the label (* Note). 6) "MINIMUM SIZE" and a value are displayed. Use [ ] or [ ] key to make the displayed value same as the MIN value specified on the label (* Note).
35CPM
F. Option paper feed tray paper guide adjustment
This adjustment is performed in the following cases: �When the option paper feed tray is installed. �When the paper size detection fails. 1) Hold and push the [MENU] key and the [OK] key, turn on the power. ("PCU DIAG MODE ***" is displayed.) * Do not touch the keys for about 8sec after releasing fingers from the above keys. 2) Push the [MENU] key several times until "SIZE ADJUSTMENT A" is displayed, and push the [OK] key. 3) "MAXIMUM SIZE" is displayed on the LCD. Pull out the cassette, open the paper guide to the maximum, return the cassette to the machine, and push the [OK] key. 4) "MINIMUM SIZE" is displayed on the LCD. Pull out the cassette again from the machine, close the paper guide to the minimum, return the cassette to the machine, and push the [OK] key.
(*Note) Label attachment position
Label