|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
The service was good but it just a little late for the download. It seems that it needs to clear the payment but the payment was settled by paypal. As far as my concern, it should be able to download after the confirmation of sold.
 ;
Great quality manual, fast service, excellent seller... Thanks !!!
 ;
Great manual and fast service. Download was possible after a few hours.
 ;
thanks a lot.
without the service manual my handycam was going to the trash.
good job, go on.
bye
 ;
This service manual is a good copy of the original, complete and fully readable. It is really useful to repair my Tv set following its clear instructions.
AY-AP18CE AH-AP18CE AE-A18CE AU-A18CE
AY-AP24CE AH-AP24CE AE-A24CE AU-A24CE
4.
Hot-Keep This function automatically controls the on-off operation of the indoor fan motor in accordance during the heating operation, thereby preventing the air conditioner from delivering a cold air when the compressor is off. When the room temperature exceeds the thermostat line �H1�, the compressor is turned off, and the indoor fan motor is turned off after rotating at �HUL� for 30 seconds. 3 minutes and 10 seconds after turning off the compressor, the indoor fan motor is turned on for 3 minutes and 20 seconds. At 10 seconds after turning on the compressor, the indoor fan motor is turned on. The next compressor OFF time is for 3, 8 or more than 8 minutes according to the room temperature (the time increases with a rise of room temperature) when 3 minutes elapse after turning on the compessor.
3 min. Compressor ON 3 min.
6. Overheating protection system When overloading occurs during the heating operation, this system controls the outdoor fan motor according to the indoor pipe temperature to prevent the overloading of the compressor and restrain the rise in high pressure. When the indoor pipe temperature exceeds U1�C, the outdoor fan motor is turned off, and when the indoor pipe temperature falls U2�C, the outdoor fan motor turns on.
OFF U1 ON
U2
U1 and U2 are defferent by the time. 1 within 3 minutes 3 over 3 minutes
Figure Y-9 Table Y-3
OFF Indoor fan motor ON OFF
30sec. 30sec.
HUL
HUL
MODELS
Fan LIne U1
HH 1 2 54�C 54�C 52�C 53�C 54�C 54�C
HAH
HM 2 53�C 52�C 53�C 52�C
1 2 1 54�C 54�C 53�C 52�C 53�C 51�C 54�C 54�C 53�C 52�C 53�C 51�C HL
Thermo off
10sec.
time
10sec.
U2 U1
Figure Y-7 5. Preheat air flow This function is intended to prevent cold air from being discharged when the heating operation starts or when defrosting. When the indoor pipe temperature is below 29�C at the begining of the heat operation or after defrosting, the indoor fan motor stays. When the indoor pipe temperature gets higher than 29�C, the fan motor is turned on at speed �HUL� after compensation of starting. When the indoor pipe temperature exceeds 35�C, the specified fan speed is restored. When the indoor pipe temperature falls below 30�C, the fan speed shifts down to "HUL". And, when the indoor pipe temperature falls below 23�C, the fan motor turns off. Then, over 29�C , it turns on again at speed �HUL�.
35
U2 MODELS Fan LIne U1 U2 U1 U2
52�C 53�C HAL 1 2 52�C 52�C 50�C 51�C 52�C 52�C 50�C 51�C
HUL 2 52�C 51�C 52�C 51�C
1 2 1 52�C 52�C 52�C 50�C 51�C 50�C 52�C 52�C 52�C 50�C 51�C 50�C
30 29 24
Pipe temperature(�C)
OFF
UL
Preset Fan speed
UL
OFF UL
Figure Y-8
21
|
|
 |
> |
|