Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
got exactly what i ordered in a very timely manner. will use again for other manuals
 ;
I'm happy. Good quality. Very helped me with my work..............................
 ;
This is the second Manual I have ordered from owner-manuals, I give it five stars because it is exactly what I expected given the age of the equipment. So the contents look a bit aged and the pictures a bit grainy, it fulfills my needs and I am glad I can still get hold of them.
 ;
thank u so much for this manual that was so cheap that i thought it was a scam but i gambled anyway because it was too good of a deal to pass up and behold,the manual has everything and details of everything even the screws and im still amazed and very happy with my manual .so take my word and jump on it before they realize how cheap they selling thier manuals..thank you so much for taking time to read my thoughts
 ;
I do not have very much to say.
The price is quite covenient, delivery was better as promised (about 12 ours, against the specified 24 hours if I remember well), and the quality of the PDF is more than acceptable.
The Service Manual of Sansui R30 itself is also satisfactory: good graphic for schematics and layouts, simple and well structured.
Giovanni Bianchi
AV-14F3/AV-1435 AV-1435EE/AV-1435TEE AV-14FMT3/AV-1438 AV-14FMG3/AV- 14FMG 3B
Measuring instrument Signal gener ator Remote control unit
Item Ad justment of VER. LIN. & VER. SCURVE
Test point
Ad justment part 4. VER. L IN. 5. VER. SCURVE � When the vertical
Description linearity has been deteriorated
rem arkably, perform the following steps. 15. Input a cross -hatch signal. 16. Select 4. VER. LIN. with the MENU �/� key. 17. Set the initial s etting value of 4. VER LIN. with the MENU - / + key. 18. Select 5. VER. SCURVE with the MENU �/ � key. 19. Set the initial setting value of 5. VER. SCURVE with the MENU - / + key.
T OP
CEN TER
20. Adjust 4. VER. LIN. and 5. VER. SCURVE so that the spaces of each line as shown in Fig.3 on TOP, CENTER and BOTTOM become uniform.
BOTT OM
Fig.3
Make sure that the adjustment is properly done on the screen of 60Hz mode. [NOTE] " Adjust to make both 50Hz & 60Hz are the same v. size and fine straight line. " When adjust again, adjust 50Hz mode first.
" When adjust in 60Hz mode, only 60Hz mode is adjust.
VSM PRESET SETTING
Item Measuring instrument Remote control unit Test point Ad justment part Description
Setting of VSM PRESET
TINT COLOUR BRIGHT CONT . SHARP
1. Enter the SERVICE MENU. 2. Select 4. VSM PRESET from the SERVICE MENU. 3. Select BRIGHT with the PICTURE MODE key. 4. Adjust the MENU �/� and MENU - / + key to bring the s et values of TINT � SHARP to the values shown in the below table. 5. Respectively select the VSM PRESET mode for SOFT and STANDARD, and make s imilar adjustment as in 3 above.
�
BRIGHT TINT COLOUR BRIGHT CONT. SHARP / :SELECT DISP : EXIT ** ** ** ** **
VSM PRESET VSM Setting Item TINT COLOUR BRIGHT CONT SHARP BRIGHT +15 +15 +15 +30 +15 STANDARD SOFT
� � �
+15
� � �
+11 +12
- / + : OPERATE
�
28