This is a very good quality print (scan) of the original SONY service manual. The original from Sony is on very thin paper. Nevertheless it is very clear and sharp and excellent readable. I'm very satisfied to have now this rare document. I've looking for it many years (infrequent). It contains very detailed circuit diagrams, exploded views, part lists, PCB view with good readable connection lines. Very recommended.
 ;
A complete manual with all the needed details of calibrations and service instructions about the radio receiver.
A big deal.
Many thanks !
 ;
Fast delivery and good quality copy. To be recommended
 ;
Excellent product, very clear print. Detailed circuit and assembly diagrams - this enabled me to repair my CD player with confidence. I highly recommend this site.
 ;
Fast access, 100% correct and complete service manual
4.7.8 PURITY AND CONVERGENCE PURITY ADJUSTMENT (1) Demagnetize CRT with the demagnetizer.
WEDGE DEFLECTION YOKE
P
(2) Loosen the retainer screw of the deflection yoke.
(3) Remove the wedges.
CRT
46
(4) Input a green raster signal from the signal generator, and turn the screen to green raster.
P/C MAGNETS
(5) Move the deflection yoke backward.
P/C MAGNETS P : PURITY MAGNET 4 : 4 POLES (convergence magnets) 6 : 6 POLES (convergence magnets)
(6) Bring the long lug of the purity magnets on the short lug and position them horizontally. (Fig.2)
Fig.1 (7) Adjust the gap between two lugs so that the GREEN RASTER will come into the center of the screen. (Fig.3)
(8) Move the deflection yoke forward, and fix the position of the deflection yoke so that the whole screen will become green.
Long lug
PURITY MAGNETS
(9) Insert the wedge to the top side of the deflection yoke so that it will not move.
Short lug
(10) Input a crosshatch signal.
Bring the long lug over the short lug and position them horizontally.
Fig.2 (11) Verify that the screen is horizontal.
(12) Input red and blue raster signals, and make sure that purity is properly adjusted.
(FRONT VIEW) GREEN RASTER
CENTER
Fig.3
(No.52122)1-29
|
|
 |
> |
|
|