Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This was precisely what I was looking for. Complete and good quality!
 ;
This is the ONLY copy of this manual I could find for a realistic price. Even Panasonic could not provide me with one.
The PDF is a very good copy and it helped me diagnose and find the fault with the unit I have.
 ;
Very complete and well reading drawings. Documentation is essential for successful repairs.Good documentation, with all that is necessary. This manual was what I was waiting with all the information necessary for the repairing I need it for. You must buy it if you want to do repairs or simply understand how it works.
 ;
Excellent service manual includes everything is need to repair this radio-caseete, how to disassemble, wiring diagram, all , waiting time until the download was only a few hours. I'm going to buy service manuals from here, are cheap and very good.Thank you.
 ;
Good service manual,i saved from scrapping this deck,is now fully functional.Thanks.
4.7.8 PURITY AND CONVERGENCE PURITY ADJUSTMENT (1) Demagnetize CRT with the demagnetizer.
WEDGE DEFLECTION YOKE
P
(2) Loosen the retainer screw of the deflection yoke.
(3) Remove the wedges.
CRT
46
(4) Input a green raster signal from the signal generator, and turn the screen to green raster.
P/C MAGNETS
(5) Move the deflection yoke backward.
P/C MAGNETS P : PURITY MAGNET 4 : 4 POLES (convergence magnets) 6 : 6 POLES (convergence magnets)
(6) Bring the long lug of the purity magnets on the short lug and position them horizontally. (Fig.2)
Fig.1 (7) Adjust the gap between two lugs so that the GREEN RASTER will come into the center of the screen. (Fig.3)
(8) Move the deflection yoke forward, and fix the position of the deflection yoke so that the whole screen will become green.
Long lug
PURITY MAGNETS
(9) Insert the wedge to the top side of the deflection yoke so that it will not move.
Short lug
(10) Input a crosshatch signal.
Bring the long lug over the short lug and position them horizontally.
Fig.2 (11) Verify that the screen is horizontal.
(12) Input red and blue raster signals, and make sure that purity is properly adjusted.
(FRONT VIEW) GREEN RASTER
CENTER
Fig.3
(No.52122)1-29
|
|
 |
> |
|