The AKAI 1720 model reel to reel tape recorder described in this Manual is quite an old unit - circa late 1960's. As a consequence, the description of the mechanical details - and adjustments thereof - is quite critical. The manual does this quite well. The schematics are also well presented and have detailed PCB overlays. Probably the only negative is that some half-tone detail has been lost from the original manual as it has been scanned in simple B&W.
 ;
Perfect source for service manuals: fast and professional transaction; high quality, perfect readable and largely scaleable PDF; complete schemes, diagrams and spare part list. Tnx a lot, cu again!!!!
AV21BT7ENS / AV21BT7ENB AV21BT7EPS / AV21BT7EPB AV21BT7EES / AV21BT7EEB
Item 4:3 HORIZONTAL SHIFT Adjustment
Measuring instruments Signal generator
Test point
Adjustment part Adjust 12 ( 4 : 3 ) Adjust 23 ( 16 : 9 ) 1. 2. 3. 4.
Description Receive a RED test pattern. Set < 4 : 3 aspect mode >. Select < ADJUST 12 > from SERVICE MENU. Change horizontal shift till the picture is horizontally centered. Check whether this adjustment is correct after completing Service Mode Adjustment. 5. Set < 16 : 9 aspect mode >. 6. Adjusts with the step which is the same above from 3 to 4 about the 16 : 9 aspect mode, too.
VERTICAL SLOPE Adjustment
Signal generator
Adjust 13 ( 4 : 3 ) Adjust 24 ( 16 : 9 )
1. 2. 3. 4.
Receive a cross-hatch signal. Set < 4 : 3 aspect mode >. Select < ADJUST 13 > from SERVICE MENU. Change vertical slope till the size of squares on both the upper and lower part of test pattern become equal to the squares laying on the vertical centre of the test pattern. Check and readjust VERTICAL SLOPE item if the adjustment becomes improper after some other geometric adjustments are done. 5. Set < 16 : 9 aspect mode >. 6. Adjusts with the step which is the same above from 3 to 4 about the 16 : 9 aspect mode, too.
VERTICAL AMPLITUDE Adjustment
Signal generator
Adjust 14 ( 4 : 3 ) Adjust 25 ( 16 : 9 )
1. 2. 3. 4.
Receive a PAL test pattern signal. Set < 4 : 3 aspect mode >. Select < ADJUST 14 > from SERVICE MENU. Change vertical slope till horizontal black lines on both the upper and lower part of the test pattern become very close to the upper and lower horizontal sides of picture tube and nearly about to disappear. Check and readjust VERTICAL AMPLITUDE item if the adjustment becomes improper after some other geometric adjustments are done. 5. Set < 16 : 9 aspect mode >. 6. Adjusts with the step which is the same above from 3 to 4 about the 16 : 9 aspect mode, too.
14