Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Exactly what was needed to assess the product - excellent value and great service
 ;
Nice to have the service manual for the Sony DCR-TRV345E now. The document is of excellent quality.
 ;
MACKIE HR824 26 pages English-only Service Manual contains:
1) HR824 technical overview with the description of front and rear panel switches.
2) HR824 specs
3) Block Diagram
4) Wiring Diagram
5) Packaging management
6) Spare part & final assembly list (for PCB rev A and B) + exploded view
7) Test Procedures (where, how to measure voltage...) including Test Point diagram on the PCB.
8) IC and Transistor charts.
Excellent guide: very clear, good scan quality enabling us to print readable diagram :-)
Note:
Mackie HR824 make extensive use of surface mount devices (SMD). Service on the HR824 must
only be undertaken by experienced service technicians with the right tools, experience and patience to perform surface mount rework when needed.
 ;
This Service manual is very well scanned and its clean to read, no any anti-theft words that un-english could understand. I got my CCD600 working with this manual and it´s clear shematics :)
 ;
I was very pleased with the service provided and was surprised at how good the quality was of the manual. I thought it may be a third generation copy or so, but it is as good as the websites that charge 3 times this much. I repair some electronics for family and friends without charge, so this is perfect for me. Thank you very much.
AV21BT7ENS / AV21BT7ENB AV21BT7EPS / AV21BT7EPB AV21BT7EES / AV21BT7EEB
Item 4:3 HORIZONTAL SHIFT Adjustment
Measuring instruments Signal generator
Test point
Adjustment part Adjust 12 ( 4 : 3 ) Adjust 23 ( 16 : 9 ) 1. 2. 3. 4.
Description Receive a RED test pattern. Set < 4 : 3 aspect mode >. Select < ADJUST 12 > from SERVICE MENU. Change horizontal shift till the picture is horizontally centered. Check whether this adjustment is correct after completing Service Mode Adjustment. 5. Set < 16 : 9 aspect mode >. 6. Adjusts with the step which is the same above from 3 to 4 about the 16 : 9 aspect mode, too.
VERTICAL SLOPE Adjustment
Signal generator
Adjust 13 ( 4 : 3 ) Adjust 24 ( 16 : 9 )
1. 2. 3. 4.
Receive a cross-hatch signal. Set < 4 : 3 aspect mode >. Select < ADJUST 13 > from SERVICE MENU. Change vertical slope till the size of squares on both the upper and lower part of test pattern become equal to the squares laying on the vertical centre of the test pattern. Check and readjust VERTICAL SLOPE item if the adjustment becomes improper after some other geometric adjustments are done. 5. Set < 16 : 9 aspect mode >. 6. Adjusts with the step which is the same above from 3 to 4 about the 16 : 9 aspect mode, too.
VERTICAL AMPLITUDE Adjustment
Signal generator
Adjust 14 ( 4 : 3 ) Adjust 25 ( 16 : 9 )
1. 2. 3. 4.
Receive a PAL test pattern signal. Set < 4 : 3 aspect mode >. Select < ADJUST 14 > from SERVICE MENU. Change vertical slope till horizontal black lines on both the upper and lower part of the test pattern become very close to the upper and lower horizontal sides of picture tube and nearly about to disappear. Check and readjust VERTICAL AMPLITUDE item if the adjustment becomes improper after some other geometric adjustments are done. 5. Set < 16 : 9 aspect mode >. 6. Adjusts with the step which is the same above from 3 to 4 about the 16 : 9 aspect mode, too.
14
No. 51878
|
|
 |
> |
|