Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Manual acquired with good resolution, complete in all its pages, very good policy of the folder where are saved all products purchased.
 ;
Service manual very complete and clear. It was very helpfull for my work.
 ;
This is the 2nd time I download manuals from this website and I can say it's what I was expecting. It contains schematic, layout (decent quality), short description, parts and dissasembly instructions. I recomend it for anyone who wants to repair/modify this device.
 ;
Very useful Service Manual! With it I was able to identify the damaged pots in my old amplifier, purchase the adequate replacements and make myself the repair.
I have again my old amplifier, still a very good one that I will keep for as many years as I can!
Thanks to Owner Manuals!
 ;
Good price for the manual and easy to locate on the site and download. Plus, just like the original. Thanks a lot.
AV-21W33 AV-21W33B
SELF-CHECK FUNCTIONS
1. Outline This model has self-check functions given below.When an abnormality has been detected,the SUB POWER is turned off and both ECO and ON TIMER LEDs flash to inform of the failure.An abnormality is detected by the signal input state of the control line connected to the microcomputer.
2. Self check items Check item Over-current protection Details of detection An over-current on the low B line is detected. Method of detection The main microcomputer detects the possible abnormality at 30msec.intervals and judges the results in every 16 time. Of the 16 times, if NG is detected more than 9 times, it is judged that there is an abnormality. State of abnormality When an abnormality has been detected, the SUB-POWER is turned off. While the SUBPOWER is being turned off, the POWER key on the remote control unit is not operational until the power cord is taken out and put in again. DITTO
CRT NECK protection
Operation of CRT NECK protection circuit
DITTO
3. Self check indicating function When an abnormality has been detected at about 5 seconds after the power is turned on,the SUB POWER is turned off immediately and the LEDs flash.
After about 5 seconds Detection of an abnormality
Power on
Start of detection
Flashing LEDs
SUB-POWER OFF
[ Indication by the LEDs]
Item 1 Over-current protection 2 CRT NECK protection Note: In case of 1 + 2, the item 1 is indicated.
LEDs flashing intervals At 0.2-second intervals At 1-second intervals
Priority of detection 1 2