This PDF is very comprehensive. It includes drawings, parts lists, schematics, pictures, PCB drawings, mechanical layouts, etc. for all three stackable equipment. The scans are good too. Easy to read and no smudges or black lines. I have no complaints. I will make this site my first stop for finding my service manuals.
 ;
This service manual includes drawings, schematics, exploded views, parts list, operating details, and more. Very good scans, very readable. The only thing that made it a 4 star rating was on approximately 4 scans only half of the page was scanned then the other half. I would have preferred the pages to be whole scans.
AV-29LS AV-29LH
AV-29LX AV-2908TEE
PURITY AND CONVERGENCE ADJUSTMENTS
Note: The final adjustment of CONVERGENCE must be done after the FOCUS adjustment. (CONVERGENCE is changed by FOCUS adjustment.) When makes difference by FOCUS adjustment, should be reconfirming PURITY adjustment.
WEDGE DEFLECTION YOKE
PURITY ADJUSTMENT
1. Demagnetize CRT with the demagnetizer. 2. Loosen the retainer screw of the deflection yoke. 3. Remove the wedges. 4. Input a green raster signal from the signal generator, and turn the screen to green raster. � P/C MAGNETS 5. Move the deflection yoke backward. 6. Bring the long lug of the purity magnets on the short lug and position them horizontally. (Fig. 2) 7. Adjust the gap between two lugs so that the GREEN RASTER will come into the centre of the screen. (Fig. 3) 8. Move the deflection yoke forward, and fix the position of the deflection yoke so that the whole screen will become green. 9. Insert the wedge to the top side of the deflection yoke so that it will not move. 10. Input a crosshatch signal. 11. Verify that the screen is horizontal.
Short lug Long lug
CRT
P
46
P/C MAGNETS
P : PURITY MAGNET 4 : 4 POLES (convergence magnets) 6 : 6 POLES (convergence magnets) Fig. 1
PURITY MAGNETS
12. Input red and blue raster signals, and make sure that purity is properly adjusted.
Bring the long lug over the short lug and position them horizontally.
Fig. 2
(FRONT VIEW)
GREEN RASTER
CENTRE
Fig. 3
34